A. ha = hl
B. ha = 2hl
C. ha = 0.5 hl
D. ha = 0.75 hl
Related Mcqs:
- For a laminar flow of fluid in a circular tube, ‘h1’ is the convective heat transfer co-efficient at velocity ‘V1’. If the velocity is reduced by half and assuming the fluid properties are constant, the new convective heat transfer co-efficient is________________?
A. 1.26 h1
B. 0.794 h1
C. 0.574 h1
D. 1.741 h1 - A composite wall consists of two plates A and B placed in series normal to the flow of heat. The thermal conductivities are kA and kB and the specific heat capacities are CPA and CPB for plates A and B respectively. Plate B has twice the thickness of plate A. At steady state, the temperature difference across plate A is greater than that across plate B, when_________________?
A. CPA > CPB
B. CPA < CPB
C. kA < 0.5 kB
D. kA >2 kB - Fouling factor for a heat exchanger is given by (where, U1 = heat transfer co-efficient of dirty surface U2 = heat transfer co-efficient of clean surface) ?
A. U1 – U2
B. 1/U1 – 1/U2
C. 1/U2 – 1/U1
D. U2 – U1 - The overall heat transfer co-efficient for a shell and tube heat exchanger for clean surfaces is U0 = 400 W/m2.K. The fouling factor after one year of operation is found to be hd0 = 2000 W/m2.K. The overall heat transfer co-efficient at this time is _____________________?
A. 1200 W/m2.K
B. 894 W/m2.K
C. 333 W/m2.K
D. 287 W/m2.K - A fluid is flowing inside the inner tube of a double pipe heat exchanger with diameter ‘d’. For a fixed mass flow rate, the tube side heat transfer co-efficient for turbulent flow conditions is proportional to_____________________?
A. d0.8
B. d-0.2
C. d-1
D. d-1.8 - A 10 cm dia steam pipe, carrying steam at 180°C, is covered with an insulation (conductivity = 0.6 W/m.°C). It losses heat to the surroundings at 30°C. Assume a heat transfer co-efficient of 0.8 W/m2.°C for heat transfer from surface to the surroundings. Neglect wall resistance of the pipe and film resistance of steam. If the insulation thickness is 2 cms, the rate of heat loss from this insulated pipe will be__________________?
A. Greater than that for un-insulated steam pipe
B. Less than that of the un-insulated steam pipe
C. Equal to that of the un-insulated steam pipe
D. Less than the steam pipe with 5 cms insulation - Convective heat transfer co-efficient in case of fluid flowing in tubes is not affected by the tube length/diameter ratio, if the flow is in the _____________ zone?
A. Laminar
B. Transition
C. Both A & B
D. Highly turbulent - 1000 Kg of liquid at 30°C in a well stirred vessel has to be heated to 120°C, using immersed coils carrying condensing steam at 150°C. The area of the steam coils is 1.2 m2 and the overall heat transfer co-efficient to the liquid is 1500 W/m2.°C. Assuming negligible heat loss to the surrounding and specific heat capacity of the liquid to be 4 kJ/kg.°C, the time taken for the liquid to reach desired temperature will be__________________?
A. 15 min
B. 22 min
C. 44 min
D. 51 min - Extended heat transfer surface like fins are used to increase the heat transfer rate. Fin efficiency is defined as the ratio of heat transferred across the fin surface to the theoretical heat transfer across an equal area held at the________________?
A. Surrounding temperature
B. Average temperature of the fin
C. Temperature of the fin end
D. Constant temperature equal to that of the base - Heat transfer by conduction in the turbulent core of a fluid flowing through a heated pipe is negligible, if the value of Prandtl number is_______________?
A. 0.2
B. 0.4
C. 0.6
D. 0.8