A. Surrounding temperature
B. Average temperature of the fin
C. Temperature of the fin end
D. Constant temperature equal to that of the base
Related Mcqs:
- A 10 cm dia steam pipe, carrying steam at 180°C, is covered with an insulation (conductivity = 0.6 W/m.°C). It losses heat to the surroundings at 30°C. Assume a heat transfer co-efficient of 0.8 W/m2.°C for heat transfer from surface to the surroundings. Neglect wall resistance of the pipe and film resistance of steam. If the insulation thickness is 2 cms, the rate of heat loss from this insulated pipe will be__________________?
A. Greater than that for un-insulated steam pipe
B. Less than that of the un-insulated steam pipe
C. Equal to that of the un-insulated steam pipe
D. Less than the steam pipe with 5 cms insulation - The equivalent diameter for the annulus of a double pipe heat exchanger, whose inner pipe has fins on the outside is ______________ compared to the same size pipes without fins?
A. More
B. Less
C. Same
D. Unpredictable - The main purpose of providing fins on heat transfer surface is to increase the_________________?
A. Temperature gradient
B. Mechanical strength of the equipment
C. Heat transfer area
D. Heat transfer co-efficient - Fouling factor for a heat exchanger is given by (where, U1 = heat transfer co-efficient of dirty surface U2 = heat transfer co-efficient of clean surface) ?
A. U1 – U2
B. 1/U1 – 1/U2
C. 1/U2 – 1/U1
D. U2 – U1 - The inner wall of a furnace is at a temperature of 700°C. The composite wall is made of two substances, 10 and 20 cm thick with thermal conductivities of 0.05 and 0.1 W.m-1.°C- 1 respectively. The ambient air is at 30°C and the heat transfer co-efficient between the outer surface of wall and air is 20 W.m-2.°C-1. The rate of heat loss from the outer surface in W.m-2is__________________?
A. 165.4
B. 167.5
C. 172.5
D. 175 - Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both the cases. The recommended arrangement is________________?
A. Finned tube heat exchanger with air inside and steam outside
B. Finned tube heat exchanger with air outside and steam inside
C. Shell and tube heat exchanger with air inside tubes and steam on shell side
D. Shell and tube heat exchanger with air on shell side and steam inside tubes - Heat transfer by conduction results due to the transfer of free electrons, kinetic energy & vibrational energy from one molecule to another. Conduction heat transfer cannot take place____________________?
A. Between two bodies in physical contact with each other
B. Between two bodies not in physical contact with each other
C. From one part of a body to the another part of the same body
D. Both B & C - The overall heat transfer co-efficient for a shell and tube heat exchanger for clean surfaces is U0 = 400 W/m2.K. The fouling factor after one year of operation is found to be hd0 = 2000 W/m2.K. The overall heat transfer co-efficient at this time is _____________________?
A. 1200 W/m2.K
B. 894 W/m2.K
C. 333 W/m2.K
D. 287 W/m2.K - For shell and tube heat exchanger, with increasing heat transfer area, the purchased cost per unit heat transfer area___________________?
A. Increases
B. Decreases
C. Remain constant
D. Passes through a maxima - Convective heat transfer, in which heat is transferred by movement of warmed matter is described by___________________?
A. Fourier’s law
B. Newton’s law of cooling
C. Fick’s law
D. None of these