A. 100 kg/cm2 and 540°C
B. 1 kg/cm2 and 100°C
C. 218 kg/cm2 abs and 373°C
D. 218 kg/cm2 abs and 540°C
E. 100 kg/cm2 abs and 373°C
Related Mcqs:
- The size of a boiler drum in pulverised fuel fired boiler,as its size and capacity, (steam pressure and flow ratings) increase __________________?
A. increases
B. decreases
C. remains unchanged
D. increases/decreases depending on steam temperature requirements
E. unpredictable - Pick up the correct statement as regards Cornish boiler and Lancashire boiler _______________?
A. cornish is fire tube and lancashire is water tube
B. cornish is water tube and lancashire is fire tube
C. cornish has two fire tubes and lancashire has one
D. lancashire has two fire tubes and cornish has one
E. both have two fire tubes - The difference between cornish boiler and lancashire boiler is that_________________?
A. former is fire tube type and latter is water tube type boiler
B. former is water tube type and latter is fire tube type
C. former contains one fire tube and latter contains two fire tubes
E. none/of the above - For the same diameter and thickness of tube, a water tube boiler compared to a fire tube boiler has ____________________?
A. more heating surface
B. less heating surface
C. equal heating surface
D. heating surface depends on other parameters
E. none of the above - The high pressure boiler is oiie producing steam at a pressure more than_________________?
A. atmospheric pressure
B. 5 kg/cm2
C. 10 kg/cm2
D. 40 kg/cm2
E. 75-80 kg/cm2 - The pressure in the air space above an oil (sp. gr. 0.8) surface in a tank is 0.1 kg/cm”. The pressure at 2.5 m below the oil surface will be __________________?
A. 2 metres of water column
B. 3 metres of water column
C. 3.5 metres of water column
D. 4 m of water column
E. none of the above - In locomotive boiler, maximum steam pressure is limited to_______________?
A. 1 kg/cm2
B. 5 kg/cm2
C. 10 kg/cm2
D. 18 kg/cm2
E. 31 kg/cm2 - It is required to produce large amount of steam at low pressure. Which boiler should be used ?
A. pulverised fuel fired boiler
B. cochran boiler
C. lancashire boiler
D. babcock and wilcox boiler
E. stoker fired boiler - Natural water circulation, by convection in water tube boilers, with increase in pressure of boiler _________________?
A. increases
B. decreases
C. remains unaffected
D. first increases and then decreases
E. first decreases and then increases - The steam temperature with increase in load in case of a boiler fitted with radiation super heater________________?
A. increases
B. decreases
C. remains unaffected
D. first increases and then decreases
E. unpredictable