A. increases
B. decreases
C. remains unaffected
D. first increases and then decreases
E. first decreases and then increases
Related Mcqs:
- The diameter of tubes for natural circulation boiler as compared to controlled circulation boilers is___________________?
A. more
B. less
C. same
D. could be more or less depending on other factors
E. none of the above - For the same diameter and thickness of tube, a water tube boiler compared to a fire tube boiler has ____________________?
A. more heating surface
B. less heating surface
C. equal heating surface
D. heating surface depends on other parameters
E. none of the above - Pick up the wrong statement about water tube boiler in comparison to fire tube boilers ______________________?
A. former generates steam at high pressure
B. former occupies less space for same power
C. rate of steam flow is more in former case
D. former is used for high installed capacity
E. chances of explosion are less in former case - In natural circulation type boiler _______________?
A. heating takes place at bottom and the water supplied at bottom gets converted into the mixture of steam bubbles and hot water which rise to drum
B. water is supplied in durm and through down-comers located in atmospheric conditon it passes to the water wall and rises to drum in the form of mixture of water and steam
C. feed pump is employed to supplement natural circulation in water wall type furnace
D. water is converted into steam in one . pass without any recirculation
E. water is fed at atmospheric pressure - The size of a boiler drum in pulverised fuel fired boiler,as its size and capacity, (steam pressure and flow ratings) increase __________________?
A. increases
B. decreases
C. remains unchanged
D. increases/decreases depending on steam temperature requirements
E. unpredictable - Steam in water tube boiler as compared to fire tube boiler_________________?
A. can be raised rapidly
B. is raisd at slower rate
C. is raised at same rate
D. could be raised at fast/slow rate depending on design
E. none of the above is true - In order to increase sensitivity of U-tube manometer, one leg is usually inclined by angle 9. Sensitivity of inclined tube to sensitivity of U-tube is equal to________________?
A. sin 9
B. sin 9
C. cas 9
D. cos 9
E. tan 9 - Fire tube boilers are limited to a maximum design working pressure of ____________________?
A. 1 kg/cm
B. 6 kg/cm
C. 17 kg/cm2
D. 100 kg/cm2
E. 250 kg/cm2 - Water tube boilers are those in which________________?
A. flue gases pass through tubes and water around it
B. water passes through the tubes and flue gases around it
C. work is done during adiabatic expansion
D. change in enthalpy
E. none of the above - The relative heat absorption for successively added equal areas of boiler convection heating surfaces____________________?
A. increases
B. decreases
C. remains unaffected
D. first increases and then decreases
E. first decreases and then increases