A. Pointer
B. Bourdon tube
C. Bulb
D. None of these
Advertisement
Related Mcqs:
- The ______________ of a vapor pressure thermometer is a primary element?
- A. Pointer B. Bourdon tube C. Bulb D. None of these...
- The _____________ of a vapor pressure thermometer is a functioning element?
- A. Pointer B. Bourdon tube C. Bulb D. None of these...
- Vapour actuated pressure spring thermometer does not require ambient temperature compensation. Ambient temperature compensation is provided in gas or liquid expansion pressure spring thermometer by__________________?
- A. Making the volume of thermometer bulb as large as conveniently possible B. Reducing the volume of the capillary to a minimum C. Reducing the volume of the receiving element to a minimum D. All A , B & C....
- To increase the speed of response of a pressure spring liquid or gas expansion thermometer, the clearance space between the thermometer bulb and the thermal well should not be filled with ________________?
- A. Air B. A metal powder or graphite C. Oil D. Mercury...
- For increased speed of response of an expansion pressure spring thermometer, the thermometer bulb should have a__________________?
- A. Large area but small mass B. High thermal conductivity C. Small specific heat D. All A , B & C...
- Ordinary mercury in glass thermometer is used for measuring temperature upto 120°C. However, for measuring higher temperature upto __________ °C, thermometer is made by filling nitrogen under pressure above the mercury, which stops the evaporation of mercury and reduces the chance of broken thread of mercury?
- A. 250 B. 350 C. 550 D. 700...
- A bimetallic thermometer as compared to industrial mercury in glass thermometer has almost the same_________________?
- A. Temperature measuring range (- 40°C to 450°C) B. Accuracy (± 1% of span) C. Speed of response D. All a, b & c...
- The frequency response of a dynamic element shows a constant magnitude ratio at all frequencies. The element exhibits a negative phase shift at all frequencies. The absolute value of the phase shift increases linearly with frequency. The element has the transfer function ?
- A. e-ηS B. (T1S + 1)/(T2S + 1) C. (T1S/(T2S + 1) D. (T1S + 1)/(T2S...
- Which of the following is never used as an element of industrial resistance thermometer ?
- A. Lead B. Nickel C. Copper D. 30% iron + 70% nickel...
- Thermistor, which has high temperature co-efficient of resistivity, is used as the sensing element in resistance thermometer. It is a/an ?
- A. Insulator B. Conductor C. Solid semi-conductor D. Liquid semi-conductor...