A. Temperature measuring range (- 40°C to 450°C)
B. Accuracy (± 1% of span)
C. Speed of response
D. All a, b & c
Advertisement
Related Mcqs:
- Ordinary mercury in glass thermometer is used for measuring temperature upto 120°C. However, for measuring higher temperature upto __________ °C, thermometer is made by filling nitrogen under pressure above the mercury, which stops the evaporation of mercury and reduces the chance of broken thread of mercury?
- A. 250 B. 350 C. 550 D. 700...
- The deflection of the free end of the bimetallic strips in a bimetallic thermometer with temperature is nearly__________________?
- A. Linear B. Non-linear C. Parabolic D. Hyperbolic...
- Working principle of mercury in glass thermometer is based on the ______________ of mercury with increase in temperature?
- A. Increase of pressure B. Increase of thermal conductivity C. Volumetric expansion D. Differential linear expansion...
- Working principle of mercury in glass thermometer is based on volumetric expansion of mercury with increase in temperature. Which of the following undergoes minimum volumetric expansion for a given temperature change ?
- A. Water B. Mercury C. Methyl alcohol D. Carbon-tetrachloride...
- Working principle of mercury in glass thermometer is__________________?
- A. Volumetric expansion B. Pressure rise with temperature C. Linear expansion D. None of these...
- A mercury thermometer cannot be used to measure the temperature below the freezing point of mercury, which is _____________ °C?
- A. -38.9 B. -11.9 C. -60.9 D. -80.9...
- Mercury thermometer is commonly used for low temperature measurement. The freezing point and boiling point of mercury are respectively _____________ °C?
- A. – 39 and 350 B. – 51 and 439 C. – 79 and 395 D. – 10 and 425...
- Vapour actuated pressure spring thermometer does not require ambient temperature compensation. Ambient temperature compensation is provided in gas or liquid expansion pressure spring thermometer by__________________?
- A. Making the volume of thermometer bulb as large as conveniently possible B. Reducing the volume of the capillary to a minimum C. Reducing the volume of the receiving element to a minimum D. All A , B & C....
- To increase the speed of response of a pressure spring liquid or gas expansion thermometer, the clearance space between the thermometer bulb and the thermal well should not be filled with ________________?
- A. Air B. A metal powder or graphite C. Oil D. Mercury...
- For increased speed of response of an expansion pressure spring thermometer, the thermometer bulb should have a__________________?
- A. Large area but small mass B. High thermal conductivity C. Small specific heat D. All A , B & C...