A. Pointer
B. Bourdon tube
C. Bulb
D. None of these
Related Mcqs:
- The ______________ of a vapor pressure thermometer is a primary element?
A. Pointer
B. Bourdon tube
C. Bulb
D. None of these - The ____________ of a vapor pressure thermometer is a secondary element ?
A. Pointer
B. Bourdon tube
C. Bulb
D. None of these - Vapour actuated pressure spring thermometer does not require ambient temperature compensation. Ambient temperature compensation is provided in gas or liquid expansion pressure spring thermometer by__________________?
A. Making the volume of thermometer bulb as large as conveniently possible
B. Reducing the volume of the capillary to a minimum
C. Reducing the volume of the receiving element to a minimum
D. All A , B & C. - To increase the speed of response of a pressure spring liquid or gas expansion thermometer, the clearance space between the thermometer bulb and the thermal well should not be filled with ________________?
A. Air
B. A metal powder or graphite
C. Oil
D. Mercury - For increased speed of response of an expansion pressure spring thermometer, the thermometer bulb should have a__________________?
A. Large area but small mass
B. High thermal conductivity
C. Small specific heat
D. All A , B & C - Ordinary mercury in glass thermometer is used for measuring temperature upto 120°C. However, for measuring higher temperature upto __________ °C, thermometer is made by filling nitrogen under pressure above the mercury, which stops the evaporation of mercury and reduces the chance of broken thread of mercury?
A. 250
B. 350
C. 550
D. 700 - A bimetallic thermometer as compared to industrial mercury in glass thermometer has almost the same_________________?
A. Temperature measuring range (- 40°C to 450°C)
B. Accuracy (± 1% of span)
C. Speed of response
D. All a, b & c - The frequency response of a dynamic element shows a constant magnitude ratio at all frequencies. The element exhibits a negative phase shift at all frequencies. The absolute value of the phase shift increases linearly with frequency. The element has the transfer function ?
A. e-ηS
B. (T1S + 1)/(T2S + 1)
C. (T1S/(T2S + 1)
D. (T1S + 1)/(T2S - Which of the following is never used as an element of industrial resistance thermometer ?
A. Lead
B. Nickel
C. Copper
D. 30% iron + 70% nickel - Thermistor, which has high temperature co-efficient of resistivity, is used as the sensing element in resistance thermometer. It is a/an ?
A. Insulator
B. Conductor
C. Solid semi-conductor
D. Liquid semi-conductor