A. 300 cm
B. 233 cm
C. 176 cm
D. 236 cm
Related Mcqs:
- If depth of slab is 10 cm, width of web 30 cm, depth of web 50 cm, centre to centre distance of beams 3 m, effective span of beams 6 m, the effective flange width of the beam, is________________?
A. 200 cm
B. 300 cm
C. 150 cm
D. 100 cm - An R.C.C beam of 25 cm width has a clear span of 5 metres and carries a U.D.L. of 2000 kg/m inclusive of its self weight. If the lever arm of the section is 45 cm., the beam is__________________?
A. Safe in shear
B. Is safe with stirrups
C. Is safe with stirrups and inclined members
D. Needs revision of the section - The floor slab of a building is supported on reinforced cement floor beams. The ratio of the end and intermediate spans is kept______________?
A. 0.7
B. 0.8
C. 0.9
D. 0.6 - A T-beam behaves as a rectangular beam of a width equal to its flange if its neutral axis______________?
A. Remains within the flange
B. Remains below the slab
C. Coincides the geometrical centre of the beam
D. None of these - An R.C.C. beam of 25 cm width and 50 cm effective depth has a clear span of 6 metres and carries a U.D.L. of 3000 kg/m inclusive of its self weight. If the lever arm constant for the section is 0.865, the maximum intensity of shear stress, is_______________?
A. 8.3 kg/cm2
B. 7.6 kg/cm2
C. 21.5 kg/cm 2
D. 11.4 kg/cm2 - A singly reinforced beam has breadth b, effective depth d, depth of neutral axis n and critical neutral axis n1. If fc and ft are permissible compressive and tensile stresses, the moment to resistance of the beam, is____________________?
A. bn (fc/2) (d – n/3)
B. Atft (d – n/3)
C. ½ n1 (1 – n1/3) cbd²
D. All the above - For a continuous floor slab supported on beams, the ratio of end span length and intermediate span length, is____________________?
A. 0.6
B. 0.7
C. 0.8
D. 0.9 - The width of the flange of a L-beam, should be less than______________?
A. One- sixth of the effective span
B. Breadth of the rib + four times thickness of the slab
C. Breadth of the rib + half clear distance between ribs
D. Least of the above - The width of the flange of a T-beam should be less than_________________?
A. One- third of the effective span of the T -beam
B. Distance between the centres of T-beam
C. Breadth of the rib plus twelve times the thickness of the slab
D. Least of the above - The width of the flange of a T-beam, which may be considered to act effectively with the rib depends upon____________________?
A. Breadth of the rib
B. Overall thickness of the rib
C. Centre to centre distance between T-beams
D. All the above