A. Remains within the flange
B. Remains below the slab
C. Coincides the geometrical centre of the beam
D. None of these
Advertisement
Related Mcqs:
- An intermediate T-beam reinforced with two layers of tensile steel with clear cover 13 cm encasted with the floor of a hall 12 metres by 7 metres, is spaced at 3 metres from adjoining beams and if the width of the beam is 20 cm, the breadth of the flange is__________________?
- A. 300 cm B. 233 cm C. 176 cm D. 236 cm...
- If depth of slab is 10 cm, width of web 30 cm, depth of web 50 cm, centre to centre distance of beams 3 m, effective span of beams 6 m, the effective flange width of the beam, is________________?
- A. 200 cm B. 300 cm C. 150 cm D. 100 cm...
- A singly reinforced beam has breadth b, effective depth d, depth of neutral axis n and critical neutral axis n1. If fc and ft are permissible compressive and tensile stresses, the moment to resistance of the beam, is____________________?
- A. bn (fc/2) (d – n/3) B. Atft (d – n/3) C. ½ n1 (1 – n1/3) cbd² D. All the above...
- The width of the flange of a L-beam, should be less than______________?
- A. One- sixth of the effective span B. Breadth of the rib + four times thickness of the slab C. Breadth of the rib + half clear distance between ribs D. Least of the above...
- The width of the flange of a T-beam should be less than_________________?
- A. One- third of the effective span of the T -beam B. Distance between the centres of T-beam C. Breadth of the rib plus twelve times the thickness of the slab D. Least of the above...
- The width of the flange of a T-beam, which may be considered to act effectively with the rib depends upon____________________?
- A. Breadth of the rib B. Overall thickness of the rib C. Centre to centre distance between T-beams D. All the above...
- The stresses developed in concrete and steel in reinforced concrete beam 25 cm width and 70 cm effective depth, are 62.5 kg/cm2 and 250 kg/cm 2 respectively. If m = 15, the depth of its neutral axis is_______________?
- A. 20 cm B. 25 cm C. 30 cm D. 35 cm...
- An R.C.C beam of 25 cm width has a clear span of 5 metres and carries a U.D.L. of 2000 kg/m inclusive of its self weight. If the lever arm of the section is 45 cm., the beam is__________________?
- A. Safe in shear B. Is safe with stirrups C. Is safe with stirrups and inclined members D. Needs revision of the section...
- effective depth and depth of the neutral axis respectively of a singly reinforced If d and n are the beam, the lever arm of the beam, is_________________?
- A. d B. n C. d + n/3 D. d – n/3...
- If the modular ratio is , steel ratio is and overall depth of a beam is , the depth of the critical neutral axis of the beam, is___________________?
- A. [m/(m – r)] d B. [m/(m + r)] d C. [(m + r)/ m] d D. [(r – m)/m] d...
Advertisement