A. 0.6
B. 0.7
C. 0.8
D. 0.9
Related Mcqs:
- The floor slab of a building is supported on reinforced cement floor beams. The ratio of the end and intermediate spans is kept______________?
A. 0.7
B. 0.8
C. 0.9
D. 0.6 - If the length of an intermediate span of a continuous slab is 5m, the length of the end span is kept_______________?
A. 4.5 m
B. 4.0 m
C. 3.5 m
D. 3.0 m - If depth of slab is 10 cm, width of web 30 cm, depth of web 50 cm, centre to centre distance of beams 3 m, effective span of beams 6 m, the effective flange width of the beam, is________________?
A. 200 cm
B. 300 cm
C. 150 cm
D. 100 cm - If K is a constant depending upon the ratio of the width of the slab to its effective span l, x is the distance of the concentrated load from the nearer support, bw is the width of the area of contact of the concentrated load measured parallel to the supported edge, the effective width of the slab be is_______________?
A. K/x (1 + x/d) + bw
B. Kx (1 – x/l) + bw
C. Kx (1 + x/l) + bw
D. All the above - An intermediate T-beam reinforced with two layers of tensile steel with clear cover 13 cm encasted with the floor of a hall 12 metres by 7 metres, is spaced at 3 metres from adjoining beams and if the width of the beam is 20 cm, the breadth of the flange is__________________?
A. 300 cm
B. 233 cm
C. 176 cm
D. 236 cm - The maximum ratio of span to depth of a slab simply supported and spanning in one direction, is______________?
A. 35
B. 25
C. 30
D. 20 - The maximum ratio of span to depth of a slab simply supported and spanning in two directions, is_________________?
A. 25
B. 30
C. 35
D. 40 - bending moment of a simply supported slab is M Kg.cm, the effective depth of the If the maximum slab is (where Q is M.R. factor)________________?
A. M/100Q
B. M/ Q
C. M/Q)
D. (M/100Q) - An R.C.C. lintel is spanning an opening of 2 m span in a brick wall. The height of the roof is 2.9 m above the floor level and that of the opening is 2.1 m above the floor level. The lintel is to be designed for self weight plus_______________?
A. Triangular load of the wall
B. UDL of wall
C. UDL of wall + load from the roof
D. Triangular load + load from the roof - If W is total load per unit area on a panel, D is the diameter of the column head, L is the span in two directions, then the sum of the maximum positive bending moment and average of the negative bending moment for the design of the span of a square flat slab, should not be less than________________?
A. WL/12 (L – 2D/3)²
B. WL/10 (L + 2D/3)²
C. WL/10 (L – 2D/3)²
D. WL/12 (L – D/3)²