A. armature current and power factor
B. terminal voltage and load factor
C. power factor and field current
D. field current and armature current
Related Mcqs:
- A synchronous motor installed at the receiving end substation operates with such an excitation that it takes power at lagging power factor. Now if the applied voltage of the synchronous motor goes down, the power factor of the synchronous motor will___________?
A. remain same
B. go down
C. improve
D. none of the above - In a synchronous motor, V-curves represent relation between____________?
A. armature current and field current
B. power factor and speed
C. field current and speed
D. field current and power factor - A synchronous motor is running with normal excitation. When the load is increased, the armature current drawn by it increases because
A. speed of the motor is reduced
B. power factor is decreased
C. Eb (back e.m.f.) becomes less than V (applied voltage)
D. Er (net resultant voltage) in armature is increased
E. none of the above - A synchronous motor can be used as a synchronous capacitor when it is____________?
A. under-loaded
B. over-loaded
C. under-excited
D. over-excited - A synchronous motor can develop synchronous torque:
A. when under loaded
B. while over-excited
C. only at synchronous speed
D. below or above synchronous speed - In case one phase of a three-phase synchronous motor is short-circuited the motor will____________?
A. not start
B. run at 2/3 of synchronous speed
C. run with excessive vibrations
D. take less than the rated load - A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?
A. synchronous motor has no slip
B. stator supply is not required to produce magnetic field
C. mechanical load on the rotor remains constant
D. synchronous motor has large airgap - While starting a salient pole synchronous motor by induction motor action and connecting field discharge resistance across field, starting and accelerating torque is produced by_____________?
A. induction motor torque in field winding
B. induction motor torque in damper winding
C. eddy current and hysteresis torque in pole faces
D. reHetance motor torque due to saliency of the rotor
E. all of the above methods - In a 3-phase synchronous motor, the negative phase sequence exists when the motor is_______________?
A. supplied with unbalanced voltage
B. under-loaded
C. over-loaded
D. none of the above - In a 3-phase, 4-pole, 50 Hz synchronous motor, the frequency, pole number and load torque all are halved. The motor speed will be____________?
A. 3000 r.p.m.
B. 1500 r.p.m.
C. 750 r.p.m.
D. none of the above