A. remain same
B. go down
C. improve
D. none of the above
Related Mcqs:
- If in a synchronous motor, driving mechanical load and drawing current at lagging power factor from constant voltage supply, its field excitation is increased, then its power factor__________?
A. become more
B. become less
C. remain constant
D. none of the above - If in a synchronous motor, driving a given mechanical load and drawing current at a leading power factor from constant voltage supply its field excitation is increased, its power factor
A. will become more
B. will become less
C. will remain unchanged
D. none of the above. - A synchronous motor connected to infinite bus-bars has at constant full load, 100% excitation and unity power factor. On changing the excitation only, the armature current will have_____________?
A. no change of power factor
B. lagging power factor with over-excitation
C. leading power factor with under-excitation
D. leading power factor with over-excitation - When a 3-phase synchronous generator is supplying a zero power factor lagging load, the armature field affects the main field in the following way
A. augments it directly
B. directly opposes it
C. cross-magnetises it
D. none of the above - A synchronous motor is running on a load with normal excitation. Now if the load on the motor is increased
A. power factor as well as armature current will decrease
B. power factor as well as armature current will increase
C. power factor will increase but armature current will decrease
D. power factor will decrease and armature current will increase - As the load is applied to a synchronous motor, the motor takes more armature current because
A. the increased load has to take more current
B. the rotor by shifting its phase backward causes motor to take more current
C. the back e.m.f. decreases causing an increase in motor current
D. the rotor strengthens the rotating field casuing more motor current - The power factor of a synchronous motor is better than that of induction motor because
A. stator supply is relieved of responsibility of producing magnetic field
B. mechanical load on the motor can be adjusted
C. synchronous motor runs at synchronous speed
D. synchronous motor has large air gap - A synchronous motor has better power factor as compared to that of an equivalent induction motor. This is mainly because?
A. synchronous motor has no slip
B. stator supply is not required to produce magnetic field
C. mechanical load on the rotor remains constant
D. synchronous motor has large airgap - A synchronous motor running with normal excitation adjusts to load increases essentially by increase in______________?
A. back e.m.f.
B. armature current
C. power factor
D. torque angle - When the excitation of an unloaded salient pole synchronous motor suddenly gets disconnected______________?
A. the motor stops
B. it runs as a reluctance motor at the same speed
C. it runs as a reluctance motor at a lower speed
D. none of the above