Select your answer based on the codes given below Codes?
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not a correct explanation of A.
C. A is true but R is false.
D. A is false but R is true
Related Mcqs:
- Assertion A : Lime based mortars give higher ratio of brickwork strength to mortar strength as compared to non-lime mortar. Reason R : Lime based mortars have lower bond strength as compared to non-lime mortars?
Select your answer according to the codes given below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - A high lime content in a composite cement-lime mortar results in______________?
Consider the following statements.
1. slow hardening.
2. quick setting.
3. weaker mortar.
select the correct statements.A. 2 and 3 are correct
B. 1 and 2 are correct
C. 1 and 3 are correct
D. 1, 2 and 3 are correct - For masonry built in 1:1:6 cement-lime-sand mix mortar or equivalent, the horizontal shear stress permissible on the area of a mortar bed joint is_______________?
A. 0.15 MPa
B. 0.125 MPa
C. 0.1 MPa
D. 0.075 MPa - Which of the following will give higher ratio of brickwork strength to mortar strength ?
A. 1 : % : 3
B. 1 : Vz: 4>/2
C. 1:1:6
D. 1:2:9 - Minimum compressive strength in N/mm2 for H1 type mortar used for masonry is_______________?
A. 3
B. 5
C. 7.5
D. 10 - Assertion A : Limiting value of slenderness ratio for a column is less than that of a wall. Reason R : A column can buckle around either of the two horizontal axes while a wall can buckle around only one axis.
Select your answer according to the codes given below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - Assertion A : From consideration of structural soundness and economy of design, most codes control the maximum slenderness ratio of masonry walls and columns. Reason R : By controlling the maximum slenderness ratio, failure is by excessive stress and not by buckling.?
Select your answer according to codes given below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not .the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - Assertion A : For eccentricity ratio exceeding 1/6, effective thickness of masonry will get reduced. Reason R : For eccentricity ratio exceeding 1/6, there will be tension on one side of the member?
Select your answer according to the codes give below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true and R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - In the case of panel wall subjected to horizontal loads at right angles to the plane of the wall, with the mortar not leaner than Ml type, tensile stress in bending in the vertical direction may be allowed to the extent of _______________?
A. 0.4 kg/cm2
B. 0.7 kg/cm2
C. 1.0 kg/cm2
D. 1.2 kg/cm2 - Rich cement mortars are more liable to cracking as compared to lean mortars because rich mortars have________________?
A. high shrinkage
B. less strength
C. both (A) and (B)
D. none of above