A. 0.4 kg/cm2
B. 0.7 kg/cm2
C. 1.0 kg/cm2
D. 1.2 kg/cm2
Related Mcqs:
- Assertion A : For identical strength, a composite cement-lime mortar is preferred over cement mortar. Reason R : Composite cement-lime mortar has higher drying shrinkage than cement mortar_____________?
Select your answer based on the codes given below Codes?
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not a correct explanation of A.
C. A is true but R is false.
D. A is false but R is true - For masonry built in 1:1:6 cement-lime-sand mix mortar or equivalent, the horizontal shear stress permissible on the area of a mortar bed joint is_______________?
A. 0.15 MPa
B. 0.125 MPa
C. 0.1 MPa
D. 0.075 MPa - The bending stress in a wall or column subjected to effective vertical load need not be considered, if the eccentricity ratio is_________________?
A. less than or equal to 1/24
B. less than or equal to 1/6
C. more than 1/24
D. less than or equal to 1/12 - Assertion A : Lime based mortars give higher ratio of brickwork strength to mortar strength as compared to non-lime mortar. Reason R : Lime based mortars have lower bond strength as compared to non-lime mortars?
Select your answer according to the codes given below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - If H is the height of wall between centers of supports, then the effective height of wall where concrete floors have a bearing on wall irrespective of the direction of span will be________________?
A. 0.75 H
B. 0.85 H
C. 1.0 H
D. 1.5 H - A free standing brick wall 20 cm thick is subjected to a wind pressure of 75kg/m2. The maximum height of wall from stability consideration is___________________?
A. 0.64 m
B. 0.96 m
C. 1.28 m
D. 1.5 m - If the eccentricity ratio is more than 1/24, then increase in the permissible stress in the design of wall subjected to eccentric loading as per code is_________________?
A. 10%
B. 25%
C. 33 1/3%
D. 50% - Assertion A : Limiting value of slenderness ratio for a column is less than that of a wall. Reason R : A column can buckle around either of the two horizontal axes while a wall can buckle around only one axis.
Select your answer according to the codes given below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - If the horizontal cross-sectional area of a wall is 1200 cm2, then the basic stress shall be multiplied by a reduction factor equal to________________?
A. 0 6
B. 0.75
C. 0.85
D. 0.95 - A 200 mm thick brick masonry wall made of modular bricks carries an axial load of 30 kN/m from wall above and an eccentric load of 20 kN/m from RCC floor acting at a distance of 47.5 mm from the centre line of the wall. The resultant eccentricity ratio is A. B. C. D. ?
A.090
B.095
C.100
D.105