A. Expansion valve
B. Condenser
C. Refrigerator
D. Compressor
Advertisement
Related Mcqs:
- What is the value of maximum COP in case of absorption refrigeration, if refrigeration provided is at temperature, TR (where, T1 and T2 are source & surrounding temperatures respectively.) ?
- A. TR/(T2 – TR) × (T1 – T2)/T1 B. TR/(T2 – TR) × T1/(T1 – T2) C. TR/(T1 – TR) × (T1 – T2)/T1 D. None of these...
- A refrigeration cycle is a reversed heat engine. Which of the following has the maximum value of the co-efficient of performance (COP) for a given refrigeration effect ?
- A. Vapor compression cycle using expansion valve B. Air refrigeration cycle C. Vapor compression cycle using expansion engine D. Carnot refrigeration cycle...
- Pressure-enthalpy chart is useful in refrigeration. The change in internal energy of an ideal fluid used in ideal refrigeration cycle is_____________________?
- A. Positive B. Negative C. Zero D. Infinity...
- Which of the following is a widely used refrigerant in vapour compression refrigeration system (using large centrifugal compressor) ?
- A. Freon B. Liquid sulphur dioxide C. Methyl chloride D. Ammonia...
- In vapour compression refrigeration system, if the evaporator temperature and the condenser temperatures are -13°C and 37°C respectively, the Carnot COP will be________________?
- A. 5.2 B. 6.2 C. 0.168 D. Data insufficient, can’t be found out...
- In case of vapour compression refrigeration system, elevating the evaporator temperature (keeping the condenser temperature constant) results in_____________?
- A. Enhanced COP B. Decreased COP C. No change in the value of COP D. Increased or decreased COP; depending upon the type of refrigerant...
- The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is__________________?
- A. Less pronounced B. More pronounced C. Equal D. Data insufficient, can’t be predicted...
- Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in__________________?
- A. Increased COP B. Same COP C. Decreased COP D. Increased or decreased COP; depending upon the type of refrigerant...
- The work done in isothermal compression compared to that in adiabatic compression will be__________________?
- A. Less B. More C. Same D. More or less depending upon the extent of work done...
- The co-efficient of performance (COP) of a refrigerating system, which is its index of performance, is defined as the ratio of useful refrigeration to the net work. The units of _____________ and COP are the same?
- A. Kinematic viscosity B. Work C. Temperature D. None of these...
Advertisement