A. 5.2
B. 6.2
C. 0.168
D. Data insufficient, can’t be found out
Advertisement
Related Mcqs:
- The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is__________________?
- A. Less pronounced B. More pronounced C. Equal D. Data insufficient, can’t be predicted...
- In case of vapour compression refrigeration system, elevating the evaporator temperature (keeping the condenser temperature constant) results in_____________?
- A. Enhanced COP B. Decreased COP C. No change in the value of COP D. Increased or decreased COP; depending upon the type of refrigerant...
- Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in__________________?
- A. Increased COP B. Same COP C. Decreased COP D. Increased or decreased COP; depending upon the type of refrigerant...
- What is the value of maximum COP in case of absorption refrigeration, if refrigeration provided is at temperature, TR (where, T1 and T2 are source & surrounding temperatures respectively.) ?
- A. TR/(T2 – TR) × (T1 – T2)/T1 B. TR/(T2 – TR) × T1/(T1 – T2) C. TR/(T1 – TR) × (T1 – T2)/T1 D. None of these...
- The efficiency of a Carnot heat engine operating between absolute temperatures T1 and T2 (when, T1 > T2) is given by (T1 – T2)/T1. The co-efficient of performance (C.O.P.) of a Carnot heat pump operating between T1 and T2 is given by__________________?
- A. T1/(T1-T2) B. T2/(T1-T2) C. T1/T2 D. T2/R1...
- The co-efficient of performance (COP) of a refrigerating system, which is its index of performance, is defined as the ratio of useful refrigeration to the net work. The units of _____________ and COP are the same?
- A. Kinematic viscosity B. Work C. Temperature D. None of these...
- A refrigeration cycle is a reversed heat engine. Which of the following has the maximum value of the co-efficient of performance (COP) for a given refrigeration effect ?
- A. Vapor compression cycle using expansion valve B. Air refrigeration cycle C. Vapor compression cycle using expansion engine D. Carnot refrigeration cycle...
- At 60° C, vapour pressure of methanol and water are 84.562 kPa and 19.953 kPa respectively. An aqueous solution of methanol at 60° C exerts a pressure of 39.223 kPa; the liquid phase and vapour phase mole fractions of methanol are 0.1686 and 0.5714 respectively. Activity co-efficient of methanol is__________________?
- A. 1.572 B. 1.9398 C. 3.389 D. 4.238...
- Which of the following units is not present in both the vapor compression refrigeration system and absorption refrigeration system ?
- A. Expansion valve B. Condenser C. Refrigerator D. Compressor...
- Which of the following is a widely used refrigerant in vapour compression refrigeration system (using large centrifugal compressor) ?
- A. Freon B. Liquid sulphur dioxide C. Methyl chloride D. Ammonia...
Advertisement