A. 5.2
B. 6.2
C. 0.168
D. Data insufficient, can’t be found out
Related Mcqs:
- The effect of changing the evaporator temperature on COP as compared to that of changing the condenser temperature (in vapour compression refrigeration system) is__________________?
A. Less pronounced
B. More pronounced
C. Equal
D. Data insufficient, can’t be predicted - In case of vapour compression refrigeration system, elevating the evaporator temperature (keeping the condenser temperature constant) results in_____________?
A. Enhanced COP
B. Decreased COP
C. No change in the value of COP
D. Increased or decreased COP; depending upon the type of refrigerant - Lowering of condenser temperature (keeping the evaporator temperature constant) in case of vapour compression refrigeration system results in__________________?
A. Increased COP
B. Same COP
C. Decreased COP
D. Increased or decreased COP; depending upon the type of refrigerant - What is the value of maximum COP in case of absorption refrigeration, if refrigeration provided is at temperature, TR (where, T1 and T2 are source & surrounding temperatures respectively.) ?
A. TR/(T2 – TR) × (T1 – T2)/T1
B. TR/(T2 – TR) × T1/(T1 – T2)
C. TR/(T1 – TR) × (T1 – T2)/T1
D. None of these - The efficiency of a Carnot heat engine operating between absolute temperatures T1 and T2 (when, T1 > T2) is given by (T1 – T2)/T1. The co-efficient of performance (C.O.P.) of a Carnot heat pump operating between T1 and T2 is given by__________________?
A. T1/(T1-T2)
B. T2/(T1-T2)
C. T1/T2
D. T2/R1 - The co-efficient of performance (COP) of a refrigerating system, which is its index of performance, is defined as the ratio of useful refrigeration to the net work. The units of _____________ and COP are the same?
A. Kinematic viscosity
B. Work
C. Temperature
D. None of these - A refrigeration cycle is a reversed heat engine. Which of the following has the maximum value of the co-efficient of performance (COP) for a given refrigeration effect ?
A. Vapor compression cycle using expansion valve
B. Air refrigeration cycle
C. Vapor compression cycle using expansion engine
D. Carnot refrigeration cycle - At 60° C, vapour pressure of methanol and water are 84.562 kPa and 19.953 kPa respectively. An aqueous solution of methanol at 60° C exerts a pressure of 39.223 kPa; the liquid phase and vapour phase mole fractions of methanol are 0.1686 and 0.5714 respectively. Activity co-efficient of methanol is__________________?
A. 1.572
B. 1.9398
C. 3.389
D. 4.238 - Which of the following units is not present in both the vapor compression refrigeration system and absorption refrigeration system ?
A. Expansion valve
B. Condenser
C. Refrigerator
D. Compressor - Which of the following is a widely used refrigerant in vapour compression refrigeration system (using large centrifugal compressor) ?
A. Freon
B. Liquid sulphur dioxide
C. Methyl chloride
D. Ammonia