A. About 9
B. Considerably more than 9
C. Considerably less than 9
D. About 3
Related Mcqs:
- In a shell and tube heat exchanger having square pitch, the shell side equivalent diameter is given by (where, P = pitch, d = outside diameter of the tube) ?
A. 4(P2 – πd2/4)/πd
B. (P2 – rd2/4)/rd
C. 4P2/πd
D. πd/4P2 - In a shell and tube heat exchanger for a given heat transfer surface area, smaller diameter tubes are favoured as compared to larger diameter ones; because the smaller diameter tubes ______________?
A. Are easier to clean
B. Are less prone to fouling
C. Can be fitted into a smaller shell diameter hence the cost of the heat exchanger would be less
D. None of these - Minimum tube pitch recommended for shell and tube heat exchangers is about _______________ times the outside diameter of the tube?
A. 1.25
B. 1.75
C. 2.5
D. 3.5 - Tubes are fixed to the tube sheet (a thick circular metallic plate) by the method of tube rolling and brazing (non-removable) or ferrule connection (removable). Thickness of the tube, sheet is normally ____________ the outside diameter of the tube but in no case it should be less than 22 mm (7/8″)?
A. Half
B. Three fourth
C. Equal to
D. 1.5 times - In most of the shell and tube heat exchangers, the tube pitch is generally ______________ the tube diameter?
A. Less than
B. 1.25-1.50 times
C. 2.5 times
D. one-fourth of - In a shell and tube heat exchanger having triangular pitch, the shell side equivalent diameter is given by________________?
A. 4(0.86P2 – πd2/4)/πd
B. (P2 – πd2/4)/πd
C. 4(0.86P2 – πd2)/πd
D. (4P2 + πd2/4)/πd - Triangular pitch tube layout as compared to square pitch in a shell and tube heat exchanger________________?
A. Permits the use of less tubes in a given shell diameter
B. Facilitates comparatively easier external cleaning because of large clearance
C. Permits the use of more tubes in a given shell diameter
D. Both B. and C. - The clearance between two tubes in a shell and tube heat exchanger is known as ‘ligament’, whose minimum value is _____________ the outside diameter of the tube, but in no case it should be less than 4.5 mm?
A. Equal to
B. Half
C. One fourth
D. Three fourth - If ‘D’ is the inside diameter of the shell of a shell and tube heat exchanger, then the baffle spacing is usually in the range of__________________?
A. D/2 or minimum 2″ to 5D
B. D/5 or minimum 2″ to 5D
C. D/5 or minimum 2″ to D
D. None of these - In case of a shell and tube heat exchanger, the minimum shell thickness for carbon steel (inclusive of corrosion allowance) depends on shell diameter and is in the range of ________________ mm?
A. 3-5
B. 5-11
C. 8-15
D. 12-18