A. D/2 or minimum 2″ to 5D
B. D/5 or minimum 2″ to 5D
C. D/5 or minimum 2″ to D
D. None of these
Related Mcqs:
- The centre to centre distance between two consecutive baffles in a shell and tube heat exchanger is called the baffle pitch or baffle spacing, which is more than 1/5th the I.D. of the shell. Which of the following is not a function of the baffles ?
A. To increase the residence time of shell side fluid
B. To provide support to the tube bundle
C. To reduce the induced vibration in the tubes
D. To increase the tube side heat transfer co-efficient by inducing turbulence - Minimum recommended baffle spacing in a shell and tube heat exchanger is about (where, D = shell diameter) ?
A. 0.2 D
B. 0.5 D
C. 0.66 D
D. 0.80 D - In case of a shell and tube heat exchanger, the minimum shell thickness for carbon steel (inclusive of corrosion allowance) depends on shell diameter and is in the range of ________________ mm?
A. 3-5
B. 5-11
C. 8-15
D. 12-18 - In a shell and tube heat exchanger having square pitch, the shell side equivalent diameter is given by (where, P = pitch, d = outside diameter of the tube) ?
A. 4(P2 – πd2/4)/πd
B. (P2 – rd2/4)/rd
C. 4P2/πd
D. πd/4P2 - Minimum baffle spacing recommended in a shell and tube heat exchanger is equal to _____________________?
A. 5 cms
B. 40% of the I.D. of the shell
C. 25 cms
D. I.D. of the shell - In a shell and tube heat exchanger for a given heat transfer surface area, smaller diameter tubes are favoured as compared to larger diameter ones; because the smaller diameter tubes ______________?
A. Are easier to clean
B. Are less prone to fouling
C. Can be fitted into a smaller shell diameter hence the cost of the heat exchanger would be less
D. None of these - Baffles are provided in a shell and tube heat exchanger to increase the turbulence and velocity of the shell side fluid. Which of the following shaped baffles does not fall in the category of transverse baffle ?
A. Segmental baffle
B. Flat plate extending across the wall
C. Disk type baffle
D. Helical type baffle - The shell side pressure drop in a shell and tube heat exchanger is maximum for _______________ baffle?
A. Disk and ring
B. Segmental
C. Orifice
D. Independent of the type of - The ratio of tube length to shell diameter in case of liquid shell and tube heat exchanger ranges from__________________?
A. 2 to 3
B. 3 to 5
C. 4 to 8
D. 6 to 12 - Ratio of tube length to shell diameter for a shell and tube heat exchanger is________________?
A. 8 : 1 to 12 : 1 for both liquid-liquid and gas-gas heat exchangers
B. 4 : 1 to 8 : 1 for liquid-liquid exchanger
C. < 4 : 1 for gas-gas exchangers
D. Both B. & C.