A. Triple point of hydrogen and freezing point of antimony
B. 13.81°K to 903.9°K
C. Both A. and B.
D. Neither A. nor B.
Advertisement
Related Mcqs:
- Platinum resistance thermometer can be used upto antimony point which is ____________ °C, and is the temperature of equilibrium between solid antimony & liquid antimony at normal atmospheric pressure?
- A. 961.93 B. 630.74 C. 1064.43 D. 1261.93...
- With increase in temperature, the electrical conductivity of the platinum used in the resistance thermometer ?
- A. Increases B. Decreases C. Remain constant D. Increases exponentially...
- Vapour actuated pressure spring thermometer does not require ambient temperature compensation. Ambient temperature compensation is provided in gas or liquid expansion pressure spring thermometer by__________________?
- A. Making the volume of thermometer bulb as large as conveniently possible B. Reducing the volume of the capillary to a minimum C. Reducing the volume of the receiving element to a minimum D. All A , B & C....
- Ordinary mercury in glass thermometer is used for measuring temperature upto 120°C. However, for measuring higher temperature upto __________ °C, thermometer is made by filling nitrogen under pressure above the mercury, which stops the evaporation of mercury and reduces the chance of broken thread of mercury?
- A. 250 B. 350 C. 550 D. 700...
- Normal mercury thermometer can be used to measure a temperature of about 300°C. However, its maximum temperature measurement range can be increased upto about 500°C by__________________?
- A. Filling nitrogen under pressure in the stem B. Increasing the diameter of the tube C. Using steel tube in place of glass tube D. Accounting for the tube expansion...
- To increase the speed of response of a pressure spring liquid or gas expansion thermometer, the clearance space between the thermometer bulb and the thermal well should not be filled with ________________?
- A. Air B. A metal powder or graphite C. Oil D. Mercury...
- Helium gas constant volume thermometer is suitable for the measurement of a temperature of ______________ °C?
- A. < 100 B. < 0 C. > 0 D. > 800...
- Mercury thermometer is commonly used for low temperature measurement. The freezing point and boiling point of mercury are respectively _____________ °C?
- A. – 39 and 350 B. – 51 and 439 C. – 79 and 395 D. – 10 and 425...
- A bimetallic thermometer as compared to industrial mercury in glass thermometer has almost the same_________________?
- A. Temperature measuring range (- 40°C to 450°C) B. Accuracy (± 1% of span) C. Speed of response D. All a, b & c...
- For increased speed of response of an expansion pressure spring thermometer, the thermometer bulb should have a__________________?
- A. Large area but small mass B. High thermal conductivity C. Small specific heat D. All A , B & C...