A. Sparingly soluble
B. Highly soluble
C. A pure substance
D. A mixture
Related Mcqs:
- With increase in the liquid flow rate at a fixed gas velocity in a randomly packed counter current gas-liquid absorption column, the gas pressure drop___________________?
A. Decreases
B. Remains unchanged
C. Increases
D. Decreases exponentially - When the gas to be dissolved in liquid is a/an ___________________ then normally co-current adsorber are used?
A. Mixture of two gases
B. Pure gas
C. Ideal gas
D. Sparingly soluble gas - Experiments were conducted to determine the flux of a species A in a stagnant medium across a gas-liquid interface. The overall mass transfer co-efficient based on the liquid side for dilute systems for the above was estimated to be 4 × 10-3 kg mole/m2.s. The equilibrium data for the system is given as y = 2x. The flux across the interface (in kg mole/m2 .s) for bulk concentrations of A in gas phase and liquid phase as y = 0.4 and x = 0.01 respectively is _________________________?
A. 5.6 × 10-4
B. 8.5 × 10-4
C. 5.6 × 10-3
D. 8.5 × 10-3 - For the gas absorption, the height of a transfer unit, based on the gas phase is given by (G: superficial molar gas velocity, L: superficial molar liquid velocity, FG: mass transfer co-efficient, moles/m2, a: interfacial area per unit volume of tower) ?
A. G/(FG . a)
B. FG/(G . a)
C. (G . a)/FG
D. L/(FG . G) - The interfacial area per unit volume of dispersion, in a gas-liquid contactor, for fractional hold up of gas = 0.1 and gas bubble diameter = 0.5 mm is given by (in m2/m3)_________________?
A. 500
B. 1200
C. 900
D. 800 - The interfacial area per unit volume of dispersion, in a gas-liquid contactor, for fractional hold up of gas = 0.1 and gas bubble diameter = 0.5 mm is given by (in m2/m3) ?
A. 500
B. 1200
C. 900
D. 800 - Which of the following is not fixed by the process requirements, in the design of absorbers ?
A. Flow rate of the entering gas
B. Composition of the entering liquid
C. Terminal concentrations of gas stream
D. None of these - Most important factor to be considered in the selection of packings for absorbers is the ______________ of packing?
A. Size
B. Durability
C. Porosity
D. Cost - Most important factor to be considered in the selection of packings for absorbers is the ______________ of packing?
A. Size
B. Durability
C. Porosity
D. Cost - For absorbers, high pressure drop results in___________________?
A. Increased efficiency
B. Decreased efficiency
C. High operating cost
D. Better gas liquid contact