A. 500
B. 1200
C. 900
D. 800
Related Mcqs:
- The interfacial area per unit volume of dispersion, in a gas-liquid contactor, for fractional hold up of gas = 0.1 and gas bubble diameter = 0.5 mm is given by (in m2/m3) ?
A. 500
B. 1200
C. 900
D. 800 - For the gas absorption, the height of a transfer unit, based on the gas phase is given by (G: superficial molar gas velocity, L: superficial molar liquid velocity, FG: mass transfer co-efficient, moles/m2, a: interfacial area per unit volume of tower) ?
A. G/(FG . a)
B. FG/(G . a)
C. (G . a)/FG
D. L/(FG . G) - In a distillation operation, what is the effect of the temperature of the reflux stream (given below) on the condenser and reboiler loads? Reflux conditions: (i) Reflux stream is completely liquid and is at its bubble point. (ii) Reflux stream is below its bubble point ?
A. Condenser and reboiler loads are the same in both the cases
B. Reboiler load is the same in both the cases but condenser load is higher in case (ii)
C. Condenser load is the same in both the cases but reboiler load is higher in case (ii)
D. Both condenser and reboiler loads are higher in case (ii) as compared to case (i) - H2S is being absorbed in a gas absorber unit. The height of the transfer unit based on the overall mass transfer coefficient on the gas side is 0.4 m. The equilibrium data is given by, y = 1.5 x. The bulk concentration of H2S has to be reduced from 0.05 to 0.001 mole fraction in the gas side. The height of the tower (in meters) corresponding to an operating line given by, y = 5x + 0.001 is ______________________?
A. 2.0
B. 1.56
C. 1.0
D. 0.56 - Experiments were conducted to determine the flux of a species A in a stagnant medium across a gas-liquid interface. The overall mass transfer co-efficient based on the liquid side for dilute systems for the above was estimated to be 4 × 10-3 kg mole/m2.s. The equilibrium data for the system is given as y = 2x. The flux across the interface (in kg mole/m2 .s) for bulk concentrations of A in gas phase and liquid phase as y = 0.4 and x = 0.01 respectively is _________________________?
A. 5.6 × 10-4
B. 8.5 × 10-4
C. 5.6 × 10-3
D. 8.5 × 10-3 - With increase in the liquid flow rate at a fixed gas velocity in a randomly packed counter current gas-liquid absorption column, the gas pressure drop___________________?
A. Decreases
B. Remains unchanged
C. Increases
D. Decreases exponentially - ______________ column is preferred to be used, when a high liquid hold up is required in a reactor for gas-liquid reaction ?
A. Packed
B. Bubble
C. Spray
D. Tray - _______________ columns are used for liquid dispersion in a continuous gas phase ?
A. Packed
B. Pulse
C. Bubble cap
D. Sieve plate - Compound A is extracted from a solution of A + B into a pure solvent S. A Co-current unit is used for the liquid-liquid extraction. The inlet rate of the solution containing A is 200 moles of B/hr.m2 and the solvent flow, rate is 400 moles of S/m2. hr. The equilibrium data is represented by Y = 3X2 , where Y is in moles of a A/moles of B and X is in moles A/moles of S. The maximum percentage extraction achieved in the unit is_________________________?
A. 25%
B. 50%
C. 70%
D. 90% - Out of the following gas-liquid contacting devices, for a given set of operating conditions, gas pressure drop is the least in ______________ tower?
A. Wetted wall
B. Bubble cap
C. Perforated tray
D. Packed