A. Both the tube sheets fixed
B. Both the tube sheets floating
C. The top tube sheet floating and bottom tube sheet fixed
D. The top tube sheet fixed and the bottom tube-sheet floating
Related Mcqs:
- Condensing film co-efficient for steam on horizontal tubes ranges from 5000 to 15000 Kcal/hr.m2.°C. Condensation of vapor is carried out inside the tube in a shell and tube heat exchanger, when the_________________?
A. Higher condensing film co-efficient is desired
B. Condensate is corrosive in nature
C. Lower pressure drop through the exchanger is desired
D. Temperature of the incoming vapor is very high - For the same heat load and mass flow rate in the tube side of a shell and tube heat exchanger, one may use multipass on the tube side, because it__________________?
A. Decreases the pressure drop
B. Decreases the outlet temperature of cooling medium
C. Increases the overall heat transfer coefficient
D. None of these - Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both the cases. The recommended arrangement is________________?
A. Finned tube heat exchanger with air inside and steam outside
B. Finned tube heat exchanger with air outside and steam inside
C. Shell and tube heat exchanger with air inside tubes and steam on shell side
D. Shell and tube heat exchanger with air on shell side and steam inside tubes - The inside heat transfer co-efficient in case of turbulent flow of liquid in the tube side in a 1-2 shell and tube heat exchanger is increased by ______________ times, when the number of tube passes is increased to 8?
A. 20.8
B. 40.8
C. 40.4
D. 20.4 - In a shell and tube heat exchanger, the tube side heat transfer co-efficient just at the entrance of the tube is_________________?
A. Infinity
B. Zero
C. Same as average heat transfer co-efficient for tube side
D. None of these - Evaporator tubes are generally_____________________?
A. Horizontal
B. Vertical
C. Inclined
D. Random - A dilute aqueous solution is to be concentrated in an evaporator system. High pressure steam is available. Multiple effect evaporator system is employed, because__________________?
A. Total heat transfer area of all the effects is -less than that in a single effect evaporator system
B. Total amount of vapor produced per Kg of feed steam in a multiple effect system is much
higher than in a single effect
C. Boiling point elevation in a single effect system is much higher than that in any effect in a
multi-effect system
D. Heat transfer co-efficient in a single effect is much lower than that in any effect in a multieffect
system - For the same heat transfer area and the terminal conditions, the ratio of the capacities of a single effect evaporator to a triple effect evaporator is_________________?
A. 3
B. 0.33
C. 1
D. 1.33 - For concentrating an aqueous solution of a material like anhydrous Na2SO4, whose solubility decreases with rise in temperature, the most suitable evaporator is a _______________ evaporator?
A. High pressure
B. Vacuum
C. Backward feed
D. None of these - Steam consumption in kg/hr in case of an evaporator is given by (where, C & E are capacity the economy of the evaporator respectively) ?
A. C/E
B. E/C
C. CE
D. 1/CE