A. Sum
B. Difference
C. Ratio
D. None of these
Related Mcqs:
- For the same heat load and mass flow rate in the tube side of a shell and tube heat exchanger, one may use multipass on the tube side, because it__________________?
A. Decreases the pressure drop
B. Decreases the outlet temperature of cooling medium
C. Increases the overall heat transfer coefficient
D. None of these - Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both the cases. The recommended arrangement is________________?
A. Finned tube heat exchanger with air inside and steam outside
B. Finned tube heat exchanger with air outside and steam inside
C. Shell and tube heat exchanger with air inside tubes and steam on shell side
D. Shell and tube heat exchanger with air on shell side and steam inside tubes - The inside heat transfer co-efficient in case of turbulent flow of liquid in the tube side in a 1-2 shell and tube heat exchanger is increased by ______________ times, when the number of tube passes is increased to 8?
A. 20.8
B. 40.8
C. 40.4
D. 20.4 - In a shell and tube heat exchanger, the tube side heat transfer co-efficient just at the entrance of the tube is_________________?
A. Infinity
B. Zero
C. Same as average heat transfer co-efficient for tube side
D. None of these - In a shell and tube heat exchanger, square pitch compared to triangular pitch__________________?
A. Gives a higher shell side pressure drop
B. Gives a lower shell side pressure drop
C. Can pack more surface area into a shell of given diameter
D. None of these - Which is the best tube arrangement (in a shell and tube heat exchanger) if the fluids are clean and non-fouling ?
A. Square pitch
B. Triangular pitch
C. Diagonal square pitch
D. None of these - In a shell and tube type heat exchanger, the floating tube bundle heat arrangement is used________________?
A. In low range of temperature differences
B. In high range of temperature differences
C. Because of its low cost
D. To prevent corrosion of the tube bundles - Condensing film co-efficient for steam on horizontal tubes ranges from 5000 to 15000 Kcal/hr.m2.°C. Condensation of vapor is carried out inside the tube in a shell and tube heat exchanger, when the_________________?
A. Higher condensing film co-efficient is desired
B. Condensate is corrosive in nature
C. Lower pressure drop through the exchanger is desired
D. Temperature of the incoming vapor is very high - In a multipass shell and tube heat exchanger, tube side return pressure loss is equal to _____________ the velocity head?
A. Twice
B. Four times
C. Square root of
D. Square of - For turbulent flow in a tube, the heat transfer co-efficient is obtained from the Dittus- Boelter correlation. If the tube diameter is halved and the flow rate is doubled, then the heat transfer co-efficient will change by a factor of________________?
A. 1
B. 1.74
C. 6.1
D. 37