A. 1
B. 1.74
C. 6.1
D. 37
Related Mcqs:
- A fluid is flowing inside the inner tube of a double pipe heat exchanger with diameter ‘d’. For a fixed mass flow rate, the tube side heat transfer co-efficient for turbulent flow conditions is proportional to_____________________?
A. d0.8
B. d-0.2
C. d-1
D. d-1.8 - The Sieder-Tate correlation for heat transfer in turbulent flow in pipe gives Nu α Re0.8, where, Nu is the Nusselt number and Re is the Reynolds number for the flow. Assuming that this relation is valid, the heat transfer co-efficient varies with the pipe diameter D. as _________________?
A. D-1.8
B. D-0.2
C. D0.2
D. D1.8 - The inside heat transfer co-efficient in case of turbulent flow of liquid in the tube side in a 1-2 shell and tube heat exchanger is increased by ______________ times, when the number of tube passes is increased to 8?
A. 20.8
B. 40.8
C. 40.4
D. 20.4 - Dittus-Boelter equation used for the determination of heat transfer co-efficient is valid ___________________?
A. For fluids in laminar flow
B. For fluids in turbulent flow
C. When Grashoff number is very important
D. For liquid metals - The overall heat transfer co-efficient for a shell and tube heat exchanger for clean surfaces is U0 = 400 W/m2.K. The fouling factor after one year of operation is found to be hd0 = 2000 W/m2.K. The overall heat transfer co-efficient at this time is _____________________?
A. 1200 W/m2.K
B. 894 W/m2.K
C. 333 W/m2.K
D. 287 W/m2.K - The Dittus-Boelter equation for convective heat transfer [(i.e. h = 0.023 (K/D) (Re)0.8 (Pr)0.4] cannot be used for________________?
A. Low Reynold’s number
B. Very low Grashoff number
C. Molten metals
D. All A., B. and C. - Steam is to be condensed in a shell and tube heat exchanger, 5 m long with a shell diameter of 1 m. Cooling water is to be used for removing the heat. Heat transfer co-efficient for the cooling water, whether on shell side or tube side is the same. The best arrangement is_____________?
A. Vertical heat exchanger with steam on tube side
B. Vertical heat exchanger with steam on shell side
C. Horizontal heat exchanger with steam on tube side
D. Horizontal heat exchanger with steam on shell side - For a laminar flow of fluid in a circular tube, ‘h1’ is the convective heat transfer co-efficient at velocity ‘V1’. If the velocity is reduced by half and assuming the fluid properties are constant, the new convective heat transfer co-efficient is________________?
A. 1.26 h1
B. 0.794 h1
C. 0.574 h1
D. 1.741 h1 - Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both the cases. The recommended arrangement is________________?
A. Finned tube heat exchanger with air inside and steam outside
B. Finned tube heat exchanger with air outside and steam inside
C. Shell and tube heat exchanger with air inside tubes and steam on shell side
D. Shell and tube heat exchanger with air on shell side and steam inside tubes - Fouling factor for a heat exchanger is given by (where, U1 = heat transfer co-efficient of dirty surface U2 = heat transfer co-efficient of clean surface) ?
A. U1 – U2
B. 1/U1 – 1/U2
C. 1/U2 – 1/U1
D. U2 – U1