A. Triple point of hydrogen and freezing point of antimony
B. 13.81°K to 903.9°K
C. Both A. and B.
D. Neither A. nor B.
Related Mcqs:
- Platinum resistance thermometer can be used upto antimony point which is ____________ °C, and is the temperature of equilibrium between solid antimony & liquid antimony at normal atmospheric pressure?
A. 961.93
B. 630.74
C. 1064.43
D. 1261.93 - With increase in temperature, the electrical conductivity of the platinum used in the resistance thermometer ?
A. Increases
B. Decreases
C. Remain constant
D. Increases exponentially - Vapour actuated pressure spring thermometer does not require ambient temperature compensation. Ambient temperature compensation is provided in gas or liquid expansion pressure spring thermometer by__________________?
A. Making the volume of thermometer bulb as large as conveniently possible
B. Reducing the volume of the capillary to a minimum
C. Reducing the volume of the receiving element to a minimum
D. All A , B & C. - Ordinary mercury in glass thermometer is used for measuring temperature upto 120°C. However, for measuring higher temperature upto __________ °C, thermometer is made by filling nitrogen under pressure above the mercury, which stops the evaporation of mercury and reduces the chance of broken thread of mercury?
A. 250
B. 350
C. 550
D. 700 - Normal mercury thermometer can be used to measure a temperature of about 300°C. However, its maximum temperature measurement range can be increased upto about 500°C by__________________?
A. Filling nitrogen under pressure in the stem
B. Increasing the diameter of the tube
C. Using steel tube in place of glass tube
D. Accounting for the tube expansion - To increase the speed of response of a pressure spring liquid or gas expansion thermometer, the clearance space between the thermometer bulb and the thermal well should not be filled with ________________?
A. Air
B. A metal powder or graphite
C. Oil
D. Mercury - Helium gas constant volume thermometer is suitable for the measurement of a temperature of ______________ °C?
A. < 100
B. < 0
C. > 0
D. > 800 - Mercury thermometer is commonly used for low temperature measurement. The freezing point and boiling point of mercury are respectively _____________ °C?
A. – 39 and 350
B. – 51 and 439
C. – 79 and 395
D. – 10 and 425 - A bimetallic thermometer as compared to industrial mercury in glass thermometer has almost the same_________________?
A. Temperature measuring range (- 40°C to 450°C)
B. Accuracy (± 1% of span)
C. Speed of response
D. All a, b & c - For increased speed of response of an expansion pressure spring thermometer, the thermometer bulb should have a__________________?
A. Large area but small mass
B. High thermal conductivity
C. Small specific heat
D. All A , B & C