A. less than or equal to 1/24
B. less than or equal to 1/6
C. more than 1/24
D. less than or equal to 1/12
Related Mcqs:
- A 200 mm thick brick masonry wall made of modular bricks carries an axial load of 30 kN/m from wall above and an eccentric load of 20 kN/m from RCC floor acting at a distance of 47.5 mm from the centre line of the wall. The resultant eccentricity ratio is A. B. C. D. ?
A.090
B.095
C.100
D.105 - Assertion A : For eccentricity ratio exceeding 1/6, effective thickness of masonry will get reduced. Reason R : For eccentricity ratio exceeding 1/6, there will be tension on one side of the member?
Select your answer according to the codes give below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true and R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - If the eccentricity ratio is more than 1/24, then increase in the permissible stress in the design of wall subjected to eccentric loading as per code is_________________?
A. 10%
B. 25%
C. 33 1/3%
D. 50% - In the case of panel wall subjected to horizontal loads at right angles to the plane of the wall, with the mortar not leaner than Ml type, tensile stress in bending in the vertical direction may be allowed to the extent of _______________?
A. 0.4 kg/cm2
B. 0.7 kg/cm2
C. 1.0 kg/cm2
D. 1.2 kg/cm2 - Assertion A : Limiting value of slenderness ratio for a column is less than that of a wall. Reason R : A column can buckle around either of the two horizontal axes while a wall can buckle around only one axis.
Select your answer according to the codes given below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - If H is the height of wall between centers of supports, then the effective height of wall where concrete floors have a bearing on wall irrespective of the direction of span will be________________?
A. 0.75 H
B. 0.85 H
C. 1.0 H
D. 1.5 H - A free standing brick wall 20 cm thick is subjected to a wind pressure of 75kg/m2. The maximum height of wall from stability consideration is___________________?
A. 0.64 m
B. 0.96 m
C. 1.28 m
D. 1.5 m - The effective height of free standing nonload bearing wall and column respectively will be_________________?
A. 1.OH and 1.OH
B. 1.5Handl.5H
C. 2.0Handl.5H
D. 2.0H and 2.0Hwhere H is the height of wall or column between centers of supports.
- For earthquake resistant masonry buildings, the vertical distance between openings one above the other in a load bearing wall shall not be less than_________________?
A. 50 cm
B. 60 cm
C. 75 cm
D. 100 cm - In a cavity wall, both leaves of which are load bearing, the effective thickness is taken as________________?
A. sum of thickness of both leaves
B. two-third of the sum of thickness of both the leaves
C. actual thickness of the stronger leaf
D. larger of (B) and (C)