A. 1.OH and 1.OH
B. 1.5Handl.5H
C. 2.0Handl.5H
D. 2.0H and 2.0H
where H is the height of wall or column between centers of supports.
Related Mcqs:
- If H is the height of wall between centers of supports, then the effective height of wall where concrete floors have a bearing on wall irrespective of the direction of span will be________________?
A. 0.75 H
B. 0.85 H
C. 1.0 H
D. 1.5 H - A free standing brick wall 20 cm thick is subjected to a wind pressure of 75kg/m2. The maximum height of wall from stability consideration is___________________?
A. 0.64 m
B. 0.96 m
C. 1.28 m
D. 1.5 m - Assertion A : Limiting value of slenderness ratio for a column is less than that of a wall. Reason R : A column can buckle around either of the two horizontal axes while a wall can buckle around only one axis.
Select your answer according to the codes given below.
A. Both A and R are true and R is the correct explanation of A.
B. Both A and R are true but R is not the correct explanation of A.
C. A is true but R is false.
D. A is false but R is true. - In a cavity wall, both leaves of which are load bearing, the effective thickness is taken as________________?
A. sum of thickness of both leaves
B. two-third of the sum of thickness of both the leaves
C. actual thickness of the stronger leaf
D. larger of (B) and (C) - If the ratio of center to center spacing of intersecting walls to actual thickness of intersecting wall is more than 20, then the stiffening coefficient for wall proper will be_________________?
A. 0
B. between 0 and 1
C. 1
D. greater than 1 - The bending stress in a wall or column subjected to effective vertical load need not be considered, if the eccentricity ratio is_________________?
A. less than or equal to 1/24
B. less than or equal to 1/6
C. more than 1/24
D. less than or equal to 1/12 - A 200 mm thick brick masonry wall made of modular bricks carries an axial load of 30 kN/m from wall above and an eccentric load of 20 kN/m from RCC floor acting at a distance of 47.5 mm from the centre line of the wall. The resultant eccentricity ratio is A. B. C. D. ?
A.090
B.095
C.100
D.105 - A 200 mm thick wall made of modular bricks is 5 m long between cross walls and 3.8 m clear height between RCC slabs at top and bottom. The slenderness ratio of the wall is________________?
A. 15
B. 19
C. 20
D. 25 - Direct load carrying capacity of a brick masonry wall standing freely as against when it supports RC slab will be___________________?
A. more
B. less
C. the same in both the cases
D. 100% - For earthquake resistant masonry buildings, the vertical distance between openings one above the other in a load bearing wall shall not be less than_________________?
A. 50 cm
B. 60 cm
C. 75 cm
D. 100 cm