A. become more
B. become less
C. remain constant
D. none of the above
Related Mcqs:
- If in a synchronous motor, driving a given mechanical load and drawing current at a leading power factor from constant voltage supply its field excitation is increased, its power factor
A. will become more
B. will become less
C. will remain unchanged
D. none of the above. - A synchronous motor installed at the receiving end substation operates with such an excitation that it takes power at lagging power factor. Now if the applied voltage of the synchronous motor goes down, the power factor of the synchronous motor will___________?
A. remain same
B. go down
C. improve
D. none of the above - A synchronous motor connected to infinite bus-bars has at constant full load, 100% excitation and unity power factor. On changing the excitation only, the armature current will have_____________?
A. no change of power factor
B. lagging power factor with over-excitation
C. leading power factor with under-excitation
D. leading power factor with over-excitation - When a 3-phase synchronous generator is supplying a zero power factor lagging load, the armature field affects the main field in the following way
A. augments it directly
B. directly opposes it
C. cross-magnetises it
D. none of the above - A synchronous motor is running on a load with normal excitation. Now if the load on the motor is increased
A. power factor as well as armature current will decrease
B. power factor as well as armature current will increase
C. power factor will increase but armature current will decrease
D. power factor will decrease and armature current will increase - A synchronous motor is running with normal excitation. When the load is increased, the armature current drawn by it increases because
A. speed of the motor is reduced
B. power factor is decreased
C. Eb (back e.m.f.) becomes less than V (applied voltage)
D. Er (net resultant voltage) in armature is increased
E. none of the above - In a synchronous motor running with fixed excitation, when the load is increased three times, its torque angle becomes approximately
A. one-third
B. twice
C. thrice
D. six times
E. nine times - If excitation of a synchronous motor running with a constant load is decreased from its normal value, ignoring effects of armature reaction, it leads to____________?
A. increase in both armature current and power factor angle
B. increase in back e.m.f. but decrease in armature current
C. increase in both armature current and power factor which is lagging
D. increase in torque angle but decrease in back e.m.f. - When load on an over-excited or under excited synchronous*motor is increased, rate of change of its armature current as compared with that of power factor is___________?
A. more
B. less
C. equal
D. twice - A synchronous motor which works on a leading power factor and does not drive a mechanical load is called as_________?
A. static condenser
B. condenser
C. synchronous condenser
D. none of the above