A. static condenser
B. condenser
C. synchronous condenser
D. none of the above
Related Mcqs:
- A synchronous motor installed at the receiving end substation operates with such an excitation that it takes power at lagging power factor. Now if the applied voltage of the synchronous motor goes down, the power factor of the synchronous motor will___________?
A. remain same
B. go down
C. improve
D. none of the above - If in a synchronous motor, driving a given mechanical load and drawing current at a leading power factor from constant voltage supply its field excitation is increased, its power factor
A. will become more
B. will become less
C. will remain unchanged
D. none of the above. - If in a synchronous motor, driving mechanical load and drawing current at lagging power factor from constant voltage supply, its field excitation is increased, then its power factor__________?
A. become more
B. become less
C. remain constant
D. none of the above - A synchronous motor working at leading power factor can be used as____________?
A. voltage booster
B. phase advancer
C. noise generator
D. mechanical synchronizer - The induced e.m.f. in a synchronous motor working on leading power factor will be_____________?
A. more than the supply voltage
B. less than the supply voltage
C. equal to the supply voltage
D. None of these - A synchronous motor is running on a load with normal excitation. Now if the load on the motor is increased
A. power factor as well as armature current will decrease
B. power factor as well as armature current will increase
C. power factor will increase but armature current will decrease
D. power factor will decrease and armature current will increase - If load (or torque) angle of a 4-pole synchronous motor is 6° electrical, its value in mechanical degrees is__________?
A. 2
B. 3
C. 4
D. 6 - A synchronous motor connected to infinite bus-bars has at constant full load, 100% excitation and unity power factor. On changing the excitation only, the armature current will have_____________?
A. no change of power factor
B. lagging power factor with over-excitation
C. leading power factor with under-excitation
D. leading power factor with over-excitation - When load on an over-excited or under excited synchronous*motor is increased, rate of change of its armature current as compared with that of power factor is___________?
A. more
B. less
C. equal
D. twice - The power factor of a synchronous motor is better than that of induction motor because
A. stator supply is relieved of responsibility of producing magnetic field
B. mechanical load on the motor can be adjusted
C. synchronous motor runs at synchronous speed
D. synchronous motor has large air gap