A. locomotive boiler
B. Babcock and Wilcox boiler
C. Stirling boiler.
D. all of the above
E. none of the above
Related Mcqs:
- For the same diameter and thickness of tube, a water tube boiler compared to a fire tube boiler has ____________________?
A. more heating surface
B. less heating surface
C. equal heating surface
D. heating surface depends on other parameters
E. none of the above - Pick up the wrong statement about water tube boiler in comparison to fire tube boilers ______________________?
A. former generates steam at high pressure
B. former occupies less space for same power
C. rate of steam flow is more in former case
D. former is used for high installed capacity
E. chances of explosion are less in former case - Steam in water tube boiler as compared to fire tube boiler_________________?
A. can be raised rapidly
B. is raisd at slower rate
C. is raised at same rate
D. could be raised at fast/slow rate depending on design
E. none of the above is true - In accelerated circulation type boiler________________?
A. heating takes place at bottom and the water supplied at bottom gets converted into the mixture of stdam bubbles and hot water which rise to durm
B. water is supplied in drum and through downcomers” located in atmospheric conditon it passes to the water wall and rises to durm in the from of mixture of water and steam
C. feed pump is employed to supplement natural circulation in water wall type furnace
E. water is converted into steam in one pass without any recirculation
E. water is fed under high pressure and high velocity - In order to increase sensitivity of U-tube manometer, one leg is usually inclined by angle 9. Sensitivity of inclined tube to sensitivity of U-tube is equal to________________?
A. sin 9
B. sin 9
C. cas 9
D. cos 9
E. tan 9 - Fire tube boilers are those in which__________________?
A. flue gases pass through tubes and water around it
B. water passes through the tubes and flue gases around it
C. forced circulation takes place
D. tubes are laid vertically
E. none of the above - The diameter of fire tube of Cornish boiler compared to its shell is__________________?
A. one half
B. one third
C. one-fifth
D. two-fifth
E. three-fifth - Fire tube boilers are limited to a maximum design working pressure of ____________________?
A. 1 kg/cm
B. 6 kg/cm
C. 17 kg/cm2
D. 100 kg/cm2
E. 250 kg/cm2 - The rise or depression of liquid in a tube due to surface tensionwim increase in size of tube will________________?
A. increase
B. remain unaffected
C. may increase or decrease depending on the characteristics of liquid
D. decrease
E. unpredictable - The fire tubes in, a Coarran and Scotish marine boiler are_________________?
A. horizontal
B. vertical
C. inclined
D. both horizontal and vertical
E. horizontal and inclined