A. same
B. more
C. less
D. more/less depending on rating
E. unpredictable
Related Mcqs:
- The C.O.P of a refrigeration cycle with increase in evaporator temperature, keeping condenser temperature constant, will______________________?
A. increase
B. decrease
C. remain unaffected
D. may increase or decrease depending on the type of refrigerant used
E. unpredictable - The C.O.P. of a refrigeration cycle with lowering of condenser temperature, keeping the evaporator temperature constant, will__________________?
A. increase
B. decrease
C. may increase or decrease depending on the type of refrigerant used
D. remain unaffected
E. unpredictable - A refrigeration cycle operates between condenser temperature of + 27°C and evaporator temperature of- 23°C. The Cannot coefficient of performance of cycle will be_________________?
A. 0.2
B. 1.2
C. 5
D. 6
E. 10 - If a heat pump cycle operates between the condenser temperature of +27°C and evaporator temperature of – 23°C, then the Carnot COP will be_________________?
A. 0.2
B. 1.2
C. 5
D. 6
E. 10 - The change in evaporator temperature in a refrigeration cycle, as compared to change in condenser temperature, influences the value of C.O.P_____________________?
A. more
B. less
C. equally.
D. unpredictable
E. none of the above - For better COP of refrigerator, the pressure range corresponding to temperature in evaporator and condenser must be____________________?
A. small
B. high
C. euqal
D. anything
E. under some conditions small and under some conditions high - The refrigeration effect in a dry evaporator compared to flooded evaporator in a similar plant is_________________?
A. same
B. more
C. less
D. more or less depending on ambient conditions
E. unpredictable - In a flooded evaporator refrigerator, an accumulator at suction of compressor is used to___________________?
A. collect liquid refrigerant and prevent it from going to compressor
B. detect liquid in vapour
C. superheat the vapour
D. collect vapours
E. increase refrigeration effect - In refrigerator, liquid receiver is required between condenser and flow controlling device, if quantity of refrigerant for system is_____________________?
A. less than 2 kg
B. more than or equal to 3.65 kg
C. more than 10 kg
D. there is no such consideration
E. pone of the above - Highest temperature encountered in refrigeration cycle should be________________?
A. near critical temperature of refrigerant
B. above critical temperature
C. at critica. temperature
D. much below critical temperature
E. could be anywhere