A. iron losses in stator will be negligible as compared to that in rotor
B. iron losses in motor will be neg¬ligible as compared to that in rotor
C. iron losses in stator will be less than that in rotor
D. iron losses in stator will be more than that in rotor
Related Mcqs:
- A 3-phase induction motor stator delta connected, is carrying full load and one of its fuses blows out. Then the motor_______________?
A. will continue running burning its one phase
B. will continue running burning its two phases
C. will stop and carry heavy current causing permanent damage to its winding
D. will continue running without any harm to the winding - In three-phase squirrel-cage induction motors____________?
A. rotor conductor ends are short-circuited through slip rings
B. rotor conductors are short-circuited through end rings
C. rotor conductors are kept open
D. rotor conductors are connected to insulation - In a three-phase induction motor, the number of poles in the rotor winding is always__________?
A. zero
B. more than the number of poles in stator
C. less than number of poles in stator
D. equal to number of poles in stator - In three-phase induction motors sometimes copper bars are placed deep in the rotor to___________?
A. improve starting torque
B. reduce copper losses
C. improve efficiency
D. improve power factor - In a three-phase induction motor__________?
A. power factor at starting is high as compared to that while running
B. power factor at starting is low as compared to that while running
C. power factor at starting in the same as that while running - Temperature of the stator winding of a three phase induction motor is obtained by___________?
A. resistance rise method
B. thermometer method
C. embedded temperature method
D. all above methods - The starting torque of a three phase induction motor can be increased by__________?
A. increasing slip
B. increasing current
C. both A. and (b)
D. none of the above - A 3-phase 440 V, 50 Hz induction motor has 4% slip. The frequency of rotor e.m.f. will be____________?
A. 200 Hz
B. 50 Hz
C. 2 Hz
D. 0.2 Hz - A 3-phase induction motor delta connected is carrying too heavy load and one of its fuses blows out. Then the motor______________?
A. will continue running burning its one phase
B. will continue running burning its two phase
C. will stop and carry heavy current causing permanent damage to its winding
D. will continue running without any harm to the winding - The starting torque of a 3-phase squirrel cage induction motor is____________?
A. twice the full load torque
B. 1.5 times the full load torque
C. equal to full load torque