A. One-fourth the width of the panel
B. Half the width of the panel
C. Radius of the column
D. Diameter of the column
Related Mcqs:
- If K is a constant depending upon the ratio of the width of the slab to its effective span l, x is the distance of the concentrated load from the nearer support, bw is the width of the area of contact of the concentrated load measured parallel to the supported edge, the effective width of the slab be is_______________?
A. K/x (1 + x/d) + bw
B. Kx (1 – x/l) + bw
C. Kx (1 + x/l) + bw
D. All the above - If depth of slab is 10 cm, width of web 30 cm, depth of web 50 cm, centre to centre distance of beams 3 m, effective span of beams 6 m, the effective flange width of the beam, is________________?
A. 200 cm
B. 300 cm
C. 150 cm
D. 100 cm - the column head support a flat slab, is generally kept The diameter of_____________?
A. 0.25 times the span length
B. 0.25 times the diameter of the column
C. 4.0 cm larger than the diameter of the column
D. 5.0 cm larger than the diameter of the column - Enlarged head of a supporting column of a flat slab is technically known as______________?
A. Supporting end of the column
B. Top of the column
C. Capital
D. Drop panel - Thickened part of a flat slab over its supporting column, is technically known as_____________?
A. Drop panel
B. Column head
C. Top of the column
D. None of these - If W is total load per unit area on a panel, D is the diameter of the column head, L is the span in two directions, then the sum of the maximum positive bending moment and average of the negative bending moment for the design of the span of a square flat slab, should not be less than________________?
A. WL/12 (L – 2D/3)²
B. WL/10 (L + 2D/3)²
C. WL/10 (L – 2D/3)²
D. WL/12 (L – D/3)² - bending moment of a simply supported slab is M Kg.cm, the effective depth of the If the maximum slab is (where Q is M.R. factor)________________?
A. M/100Q
B. M/ Q
C. M/Q)
D. (M/100Q) - The effective span of a simply supported slab, is_______________?
A. Distance between the centres of the bearings
B. Clear distance between the inner faces of the walls plus twice the thickness of the wall
C. Clear span plus effective depth of the slab
D. None of these - If the length of a combined footing for two columns l metres apart is L and the projection on the left side of the exterior column is x, then the projection y on the right side of the exterior column, in order to have a uniformly distributed load, is (where is the distance of centre of gravity of column loads______________?
A. y = L – (l – ) )
B. y = L/2 + (l –
C. y = L/2 – (l + )
D. y = L/2 – (l – ) - A column is regarded as long column if the ratio of its effective length and lateral dimension, exceeds_________________?
A. 10
B. 15
C. 20
D. 25