A. One diameter of thinner bar
B. One diameter of thicker bar
C. Twice the diameter of thinner bar
D. None of these
Related Mcqs:
- Minimum spacing between horizontal parallel reinforcement of the same size should not be less than________________?
A. One diameter
B. 2.5 diameters
C. 3 diameters
D. 3.5 diameters - As per IS : 456, the reinforcement in a column should not be less than________________?
A. 0.5% and not more than 5% of cross-sectional area
B. 0.6% and not more than 6% of cross-sectional area
C. 0.7% and not more than 7% of cross-sectional area
D. 0.8% and not more than 8% of cross-sectional area - The diameter of transverse reinforcement of columns should be equal to one-fourth of the diameter of the main steel rods but not less than________________?
A. 4 mm
B. 5 mm
C. 6 mm
D. 7 mm - The spacing of transverse reinforcement of column is decided by the following consideration_______________?
A. The least lateral dimension of the column
B. Sixteen times the diameter of the smallest longitudinal reinforcing rods in the column
C. Forty-eight times the diameter of transverse reinforcement
D. All the above - The diameter of main bars in R.C.C. columns, shall not be less than________________?
A. 6 mm
B. 8 mm
C. 10 mm
D. 12 mm - If W is total load per unit area on a panel, D is the diameter of the column head, L is the span in two directions, then the sum of the maximum positive bending moment and average of the negative bending moment for the design of the span of a square flat slab, should not be less than________________?
A. WL/12 (L – 2D/3)²
B. WL/10 (L + 2D/3)²
C. WL/10 (L – 2D/3)²
D. WL/12 (L – D/3)² - The minimum thickness of the cover at the end of a reinforcing bar should not be less than twice the diameter of the bar subject to a minimum of___________________?
A. 10 mm
B. 15 mm
C. 20 mm
D. 25 mm - The percentage of minimum reinforcement of the gross sectional area in slabs, is________________?
A. 0.10 %
B. 0.12 %
C. 0.15 %
D. 0.18 % - In the zone of R.C.C. beam where shear stress is less than 5 kg/cm2, nominal reinforcement is provided at a pitch of________________?
A. One -half lever arm of the section
B. One-third lever arm of the section
C. Lever arm of the section
D. One and half lever arm of the section - The length of lap in tension reinforcement should not be less than the bar diameter × (actual tension / four times the permissible average bond stress) if it is more than_______________?
A. 18 bar diameters
B. 24 bar diameters
C. 30 bar diameters
D. 36 bar diameters