A. 1 to 1.5
B. 2.5 to 3.5
C. 4 to 5
D. 6 to 8
Related Mcqs:
- Multiple blade paddle agitator is used for mixing high viscosity liquids/paste in which the paddle diameter is commonly 0.8 times the tank diameter. However, the width of the blade is in the range of ______________ times the paddle diameter?
A. 0.1 to 0.25
B. 0.3 to 0.5
C. 0.5 to 0.6
D. 0.65 to 0.80 - The safe height (h) to diameter D. ratio (i.e., h/d) for liquid/petro fuel storage tank of capacity more than 45 kilolitres is less than _________________?
A. 1
B. 2
C. 3
D. 3.5 - The safe distance of habitation from a hazardous chemical plant (TLV of its product < 1000 ppm) should be about ______________ kms?
A. 1
B. 5
C. 15
D. 25 - The diameter of a propeller agitator used in agitation tank ranges from ____________ percent of the tank diameter and its peripheral speed is normally 300 to 500 metres/minute ?
A. 5 to 10
B. 15 to 30
C. 40 to 50
D. 55 to 75 - Liquid/petroleum fuel storage tanks are built underground (as in case of petrol pumps), when the storage capacity is less than ______________ kilolitres?
A. 20
B. 30
C. 45
D. 85 - Cylindrical storage tanks used for the storage of volatile liquids (e.g., naphtha) have ______________ roofs?
A. Conical
B. Flat
C. Floating
D. Fixed - The testing pressure of storage tanks and pressure vessels designed as per Indian standard codes should be about ______________ times the design pressure?
A. 1.5 to 2
B. 3 to 4
C. 4 to 5
D. > 5 - Hazards associated with the relief valve leakage for extremely hazardous material storage can be taken care of by providing___________________?
A. Rupture diaphragm
B. Dikes
C. Surge chamber
D. None of these - The approximate liquid depth in an agitation tank is equal to (where, d = tank diameter)_________________?
A. 0.5 d
B. 0.75 d
C. d
D. 2 d - The minimum shell thickness for tank ≤ 15 metres diameter is limited to _______________ mm, for reasons of elastic stability?
A. 2
B. 5
C. 10
D. 15