A. Guard against corrosive and oxidising action on thermocouple materials
B. Reduce measuring lag
C. Increase the fidelity
D. Increase the sensitivity
Related Mcqs:
- Thermal wells used in temperature measurements should have __________________?
A. Very thick walls
B. Low emissivity
C. Polished surface
D. High transmissivity of radiation - Thermal conductivity based continuous flue gas analyser makes use of varying thermal conductivity of the constituents of flue gases. Which of the following constituents of flue gases has the maximum thermal conductivity ?
A. CO2
B. N2
C. O2
D. CO - Normal mercury thermometer can be used to measure a temperature of about 300°C. However, its maximum temperature measurement range can be increased upto about 500°C by__________________?
A. Filling nitrogen under pressure in the stem
B. Increasing the diameter of the tube
C. Using steel tube in place of glass tube
D. Accounting for the tube expansion - Water is flowing through a series of four tanks and getting heated as shown in figure. It is desired to design a cascade control scheme for controlling the temperature of water leaving the tank 4 as there is a disturbance in the temperature of a second stream entering the tank 2. Select the best place to take the secondary measurement for the second loop?
A. Tank 1
B. Tank 2
C. Tank 3
D. Tank 4 - Thermal conductivity measurement is used for the determination of________________?
A. O2 percentage in the flue gas
B. Specific gravity of petrofuels
C. Composition of an alloy
D. CO2 percentage in the flue gas - Thermal conductivity measurement com-prises the working principle of a_________________?
A. CO2 analyser
B. Polarimeter
C. Spectrometer
D. Chromatograph - Working principle of bimetallic thermometers is difference in linear co-efficient of thermal expansion of two strips of different metals welded together. Which of the following has the maximum thermal co-efficient of linear expansion ?
A. Nickel
B. Brass
C. Chromel
D. Invar - Water is entering a storage tank at a temperature T0 and flow rate Q0 and leaving at a flow rate Q and temperature T. There are negligible heat losses in the tank. The area of cross-section of the tank is A0. The model that describes the dynamic variation of temperature of water in the tank with time is given as________________?
A. Q0(T0 – T) = Ac . h (dT/dt)
B. Q0T0 – QT = Ac . h (dT/dt)
C. Q(T0 – T) = Ac . h (dT/dt)
D. Q(T0 – T) = Ac . (dTH/dt) - Helium gas constant volume thermometer is suitable for the measurement of a temperature of ______________ °C?
A. < 100
B. < 0
C. > 0
D. > 800 - Accurate temperature measurement performance of a radiation pyrometer cannot be affected, if the ?
A. Enhancement or attenuation of radiation occurs in the sighting path
B. Object and surrounding are at almost the same temperature
C. Object has varying emissivity
D. Object is transparent