A. The frequency response of a pure capacity process is unbounded
B. The phase lag of a pure time delay system decreases with increasing frequency
C. The amplitude ratio of a pure capacity process is inversely proportional to frequency
D. The amplitude ratio of a pure time delay system increases with frequency
Related Mcqs:
- Water is flowing through a series of four tanks and getting heated as shown in figure. It is desired to design a cascade control scheme for controlling the temperature of water leaving the tank 4 as there is a disturbance in the temperature of a second stream entering the tank 2. Select the best place to take the secondary measurement for the second loop?
A. Tank 1
B. Tank 2
C. Tank 3
D. Tank 4 - Pick out the wrong statement ?
A. O2, NO and NO2 exhibit paramagnetic properties as a result of unpaired electrons
B. CO2 is the strongest paramagnetic gas
C. Paramagnetic susceptibility of gases decreases with temperature
D. Paramagnetic susceptibility of gases permits the measurement of their concentration - Pick out the wrong statement ?
A. Proportional controller is normally used for level control in industrial applications
B. CSTR can be considered as a distributed parameter system
C. Distributed parameter approach gives partial differential equation
D. Non-linear behaviour is exemplified by an on-off controller - Pick out the wrong statement?
A. There is no transfer lag for a single first order system
B. Stirred tank with a water jacket exemplifies an interacting system
C. Transfer lag is a characteristic of all higher order systems (other than first order systems)
D. Transfer lag decreases as the number of stages decreases - What is the overall transfer function (C/R) of the following block diagram if G = G1. G2. G3 and H = H1.H2 ?
A. 1/(1 + GH)
B. G/(1 + GH)
C. H/(1 + GH)
D. G/(1 – GH) - Bode diagram are generated from output response of the system subjected to which of the following input ?
A. Impulse
B. Step
C. Ramp
D. Sinusoidal - Which of the following is not a variable area flow meter ?
A. Piston type meter
B. Rotameter
C. Magnetic flow meter
D. Orifice and tapered plug meter - Which of the following temperature measuring instruments need not touch the object whose temperature is being measured ?
A. Radiation/infrared pyrometer
B. Filled system thermometer
C. Mercury in glass thermometer
D. Thermo electric pyrometer - Which of the following is an undesirable dynamic characteristic of an instrument ?
A. Reproducibility
B. Dead zone
C. Time lag
D. Static error - Which of the following thermocouples has the widest temperature measurement range ?
A. Iron-constantan
B. Chromel-alumel
C. Copper-constantan
D. Platinum-platinum/rhodium