A. There is no transfer lag for a single first order system
B. Stirred tank with a water jacket exemplifies an interacting system
C. Transfer lag is a characteristic of all higher order systems (other than first order systems)
D. Transfer lag decreases as the number of stages decreases
Related Mcqs:
- Pick out the wrong statement ?
A. O2, NO and NO2 exhibit paramagnetic properties as a result of unpaired electrons
B. CO2 is the strongest paramagnetic gas
C. Paramagnetic susceptibility of gases decreases with temperature
D. Paramagnetic susceptibility of gases permits the measurement of their concentration - Pick out the wrong statement ?
A. Proportional controller is normally used for level control in industrial applications
B. CSTR can be considered as a distributed parameter system
C. Distributed parameter approach gives partial differential equation
D. Non-linear behaviour is exemplified by an on-off controller - Pick out the one which is a first order instrument ?
A. Mercury in glass thermometer (without any covering or air gap)
B. Bare metallic thermometer
C. Bare vapor pressure thermometer
D. All A., B. and C. - Pick out the first order system from among the following ?
A. Damped vibrator
B. Mercury in glass thermometer kept in boiling water
C. Interacting system of two tanks in series
D. Non-interacting system of two tanks in series - Pick out the most suitable instrument for measuring temperature in the range of-40 to 425°C ?
A. Mercury thermometer
B. Bimetallic thermometer
C. Radiation pyrometer
D. None of these - Select the correct statement from the following?
A. The frequency response of a pure capacity process is unbounded
B. The phase lag of a pure time delay system decreases with increasing frequency
C. The amplitude ratio of a pure capacity process is inversely proportional to frequency
D. The amplitude ratio of a pure time delay system increases with frequency - Mcleod gauge is used to measure the __________________?
A. Point velocity
B. Flow rate
C. Vacuum
D. Pressure - Vapour actuated pressure spring thermometer does not require ambient temperature compensation. Ambient temperature compensation is provided in gas or liquid expansion pressure spring thermometer by__________________?
A. Making the volume of thermometer bulb as large as conveniently possible
B. Reducing the volume of the capillary to a minimum
C. Reducing the volume of the receiving element to a minimum
D. All A , B & C. - Mass spectrometer is used for the composition analysis of____________________?
A. Alloys
B. Solids
C. Isotopes
D. None of these - Flow rate through an orifice is _____________ the pressure differential?
A. Proportional to
B. Inversely proportional to the square root of
C. Proportional to the square root of
D. Inversely proportional to the square of