A. Natural
B. Forced
C. Induced
D. None of these
Related Mcqs:
- Humidity chart is useful for the solution of problems concerning condensation, vaporisation and air conditioning. At a given dry bulb temperature, value of humidity obtained from the humidity chart directly, is in terms of _______________ humidity?
A. Molal
B. Relative
C. Percentage
D. None of these - Humidity chart is useful for the solution of problems concerning condensation, vaporisation and air conditioning. At a given dry bulb temperature, value of humidity obtained from the humidity chart directly, is in terms of _______________ humidity?
A. Molal
B. Relative
C. Percentage
D. None of these - Use of natural draft cooling tower is practised, when the air has low ?
A. Humidity
B. Temperature
C. Both A. & B.
D. Neither A. nor B. - A natural draft cooling tower is filled with wooden grids, which covers about _________________ percent of the tower height?
A. 10-15
B. 30-40
C. 70-80
D. 90-100 - In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the________________________?
A. Range is 15°F
B. Approach is 10°F
C. Both A. & B.
D. Neither A. nor B. - The percentage humidity is less than the relative humidity only at __________________ percent humidity?
A. Zero
B. Hundred
C. Both zero and hundred
D. None of these - An air-water vapour mixture has a dry bulb temperature of 60°C and a dew point temperature of 40°C. The total pressure is 101.3 kPa and the vapour pressure of water at 40°C and 60°C are 7.30 kPa and 19.91 kPa respectively. The humidity of air sample expressed as kg of water vapour/kg of dry air is__________________?
A. 0.048
B. 0.079
C. 0.122
D. 0.152 - The term “cooling range” in a cooling tower refers to the difference in the temperature of____________________?
A. Cold water leaving the tower and the wet bulb temperature of the surrounding air
B. Hot water entering the tower and the wet bulb temperature of the surrounding air
C. Hot water entering the tower and the cooled water leaving the tower
D. None of these - The temperature of water cooled in cooling tower is always _________________ temperature of entering air?
A. More than the wet bulb
B. Less than the wet bulb
C. Equal to the wet bulb
D. Equal to the dry bulb - If the solubilities of different components (in a liquid-liquid extraction system) increase with rise in temperature, then the temperature above which they dissolve completely is known as the critical solution temperature (CST or consolute temperature). If solubilities increase with decrease in temperature, then CST is the temperature below which they dissolve completely. If a binary system has no critical solution temperature, it implies that___________________?
A. The system comprises of partially miscible liquids
B. The system comprises of miscible liquids
C. The system comprises of an azeotrope
D. On heating, a vapor phase will appear; while on cooling, a solid phase will appear