A. Pulse column
B. Spray column
C. Mixer settler
D. Baffle tower
Related Mcqs:
- Solvent extraction is the terminology applied to the liquid-liquid extraction, which is preferred for the separation of the components of liquids, when____________________?
A. Extracting solvent is cheaply & abundantly available
B. One of the liquid components is heat sensitive
C. Viscosity of liquid components is very high
D. One of the liquid components has very high affinity towards the solvent - Compound A is extracted from a solution of A + B into a pure solvent S. A Co-current unit is used for the liquid-liquid extraction. The inlet rate of the solution containing A is 200 moles of B/hr.m2 and the solvent flow, rate is 400 moles of S/m2. hr. The equilibrium data is represented by Y = 3X2 , where Y is in moles of a A/moles of B and X is in moles A/moles of S. The maximum percentage extraction achieved in the unit is_________________________?
A. 25%
B. 50%
C. 70%
D. 90% - With increase in temperature, the rate of extraction in leaching (solid-liquid extraction system) ?
A. Increases
B. Decreases
C. Remain unaffected
D. Increases Linearly - In a liquid-liquid extraction, 10 kg of a solution containing 2 kg of solute C and 8 kg of solvent A is brought into contact with 10 kg of solvent B. Solvent A and B are completely immiscible in each other whereas solute C is soluble in both the solvents. The extraction process attains equilibrium. The equilibrium relationship between the two phases is Y* = 0.9X, where Y* is the kg of C/kg of B and X is kg of C/kg of A. Choose the correct answer?
A. The entire amount of C is transferred to solvent B
B. Less than 2 kg but more than 1 kg of C is transferred to solvent B
C. Less than 1 kg of C is transferred to B
D. No amount of C is transferred to B - Extraction of penicillin employs a ________________ extraction column?
A. Centrifugal
B. Packed
C. Plate
D. None of these - The Reynolds number of the liquid was increased 100 fold for a laminar falling film used for gas-liquid contacting. Assuming penetrating theory is applicable, the fold increase in the mass transfer co-efficient (Kc) for the same system is_______________________?
A. 100
B. 10
C. 5
D. 1 - In a solution containing 0.30 Kg mole of solute and 600 kg of solvent, the molality is_______________________?
A. 0.50
B. 0.60
C. 1
D. 2 - Chemisorption (chemical adsorption) is_______________________?
A. Same as “Van der Waals” adsorption
B. Characterised by adsorption of heat
C. An irreversible phenomenon
D. A reversible phenomenon - _____________ extractor is used for the concentration of radioactive nuclear waste?
A. Pulsed column
B. Sieve plate
C. Mixer-settler
D. Bollman - Radioactive nuclear waste is treated in____________________?
A. Mixer-settler extractor
B. Rotating-disc contactor
C. Pulsed column extractor
D. Bollman extractor