A. Vapour is in equilibrium with the liquid at the gas temperature
B. Vapour is in equilibrium with the liquid at the room temperature
C. Partial pressure of vapour equals the vapour pressure of the liquid at room temperature
D. None of these
Related Mcqs:
- The feed to fractionating column is changed from saturated vapour to saturated liquid. If the separation and reflux ratio remains unchanged, the number of ideal stages will______________________?
A. Increase
B. Decrease
C. Remain same
D. Depend on saturated boiling point; may increase or decrease - On moving the feed line (q-line) from saturated liquid feed (vertical position) to saturated vapor feed (horizontal feed), if the slope of both the operating lines are to be increased, then it will result in______________________?
A. Greater degree of separation with a fixed number of trays
B. Increased reboiler load
C. Increased reflux ratio
D. None of these - The relative saturation of a partially saturated mixture of vapour and gas can be increased by ________________ of the mixture?
A. Reducing the total pressure
B. Increasing the total pressure
C. Reducing the temperature
D. Both B. and C. - The dew point of a saturated gas phase equals the ________________ temperature?
A. Gas
B. Room
C. Wet bulb
D. None of these - The temperature to which a vapour gas mixture must be cooled (at varying humidity) to become saturated is called the ______________ temperature?
A. Dew point
B. Wet bulb
C. Dry bulb
D. None of these - _____________ is the temperature at which a gas-vapor mixture becomes saturated, when cooled at constant total pressure out of contact with a liquid ?
A. Dew point
B. Bubble point
C. Dry bulb temperature
D. Wet bulb temperature - For the gas absorption, the height of a transfer unit, based on the gas phase is given by (G: superficial molar gas velocity, L: superficial molar liquid velocity, FG: mass transfer co-efficient, moles/m2, a: interfacial area per unit volume of tower) ?
A. G/(FG . a)
B. FG/(G . a)
C. (G . a)/FG
D. L/(FG . G) - With increase in the liquid flow rate at a fixed gas velocity in a randomly packed counter current gas-liquid absorption column, the gas pressure drop___________________?
A. Decreases
B. Remains unchanged
C. Increases
D. Decreases exponentially - The interfacial area per unit volume of dispersion, in a gas-liquid contactor, for fractional hold up of gas = 0.1 and gas bubble diameter = 0.5 mm is given by (in m2/m3)_________________?
A. 500
B. 1200
C. 900
D. 800 - The interfacial area per unit volume of dispersion, in a gas-liquid contactor, for fractional hold up of gas = 0.1 and gas bubble diameter = 0.5 mm is given by (in m2/m3) ?
A. 500
B. 1200
C. 900
D. 800