A. 100
B. > 100
C. < 100
D. None of these
Related Mcqs:
- The ratio of Murphree plate efficiency to point efficiency is always > 1 in a _______________ flow model?
A. Plug
B. Perfectly mixed
C. Both A. & B.
D. Neither A. nor B. - The ratio of Murphree plate efficiency to point efficiency is 1 in a ______________________ flow model?
A. Plug
B. Perfectly mixed
C. Both A. & B.
D. Neither A. nor B. - If the overall efficiency and Murphree plate efficiency are equal, then both the equilibrium and operating lines are_______________?
A. Straight
B. Parallel
C. Both A. & B.
D. Neither A. nor B. - Experiments were conducted to determine the flux of a species A in a stagnant medium across a gas-liquid interface. The overall mass transfer co-efficient based on the liquid side for dilute systems for the above was estimated to be 4 × 10-3 kg mole/m2.s. The equilibrium data for the system is given as y = 2x. The flux across the interface (in kg mole/m2 .s) for bulk concentrations of A in gas phase and liquid phase as y = 0.4 and x = 0.01 respectively is _________________________?
A. 5.6 × 10-4
B. 8.5 × 10-4
C. 5.6 × 10-3
D. 8.5 × 10-3 - In a moderately sized packed absorption tower, channelling (which is most severe with stacked packings) can be minimised by taking the ratio of tower diameter to packing diameter ?
A. > 4 :1
B. < 8 : 1
C. > 8:1
D. < 6:1 - At the same gas flow rate, the pressure drop in a packed tower being irrigated with liquid _______________ that in dry packed tower ?
A. Is greater than
B. Is lower than
C. Is same as
D. Cannot be predicted as data are insufficient - Pressure drop through plate tower as compared to that through packed tower, for the same duty will be___________________?
A. Less
B. More
C. Equal
D. Either A. or B.; depends on the packing height - A packed tower compared to a plate tower for a particular mass transfer operation__________________?
A. Incurs smaller pressure drop
B. Allows installation of cooling coils
C. Is less costly when built in large sizes/diameters
D. Is more suitable, if suspended solids are present in fluid streams - Can the efficiency of a plate in the distillation tower be greater than 100% ?
A. Yes
B. Normally not; but is possible if infinite number of plates are put
C. Never
D. Yes; if the reflux ratio is maximum - Can the efficiency of a plate in the distillation tower be greater than 100% ?
A. Yes
B. Normally not; but is possible if infinite number of plates are put
C. Never
D. Yes; if the reflux ratio is maximum