A. High evaporation losses of water
B. High pressure drop of the gas
C. Difficulty in its fabrication
D. None of these
Related Mcqs:
- The reason for preferring packed towers over plate towers in distillation practice is that the packed tower operation gives___________________?
A. Low pressure drop and high hold up
B. High pressure drop and low hold up
C. Low pressure drop and low hold up
D. High pressure drop and high hold up - In a distillation operation, what is the effect of the temperature of the reflux stream (given below) on the condenser and reboiler loads? Reflux conditions: (i) Reflux stream is completely liquid and is at its bubble point. (ii) Reflux stream is below its bubble point ?
A. Condenser and reboiler loads are the same in both the cases
B. Reboiler load is the same in both the cases but condenser load is higher in case (ii)
C. Condenser load is the same in both the cases but reboiler load is higher in case (ii)
D. Both condenser and reboiler loads are higher in case (ii) as compared to case (i) - Plate towers are preferred to packed towers, when large temperature changes are involved, because of the reason that the____________________?
A. Packing may be crushed due to thermal expansion/contraction of the components of the
equipments
B. Pressure drop in the equipment will be very high
C. Viscosity variation of the fluids may cause channelling/flooding
D. None of these - The equipment frequently used for adiabatic humidification-cooling operation with recirculating liquid is_________________?
A. Natural draft cooling tower
B. Induced draft cooling tower
C. Spray chamber
D. None of these - With decrease in the throughput (compared with the design capacity) for a bubble cap distillation column, its efficiency____________________?
A. Increases
B. Decreases
C. Remain same
D. May increase or decrease; depends on individual design - Humidification involves mass transfer between a pure liquid phase and a fixed gas, which is___________________?
A. Insoluble in the liquid
B. Soluble in the liquid
C. Non-ideal in nature
D. At a fixed temperature - Water entrained by circulating air in cooling towers is termed as________________?
A. Drift
B. Blow down
C. Vapor load
D. None of these - Pick out the wrong statement pertaining to the cooling towers ?
A. In case of induced draft cooling tower, the fan is placed at the top of the tower
B. Effectiveness of forced draft cooling tower is reduced by the recirculation of the humid and
hot discharged air
C. A natural draft cooling tower is recommended to be used, when the air humidity is low and air
temperature is also low
D. Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb
temperature - Pick out the wrong statement pertaining to the cooling towers ?
A. In case of induced draft cooling tower, the fan is placed at the top of the tower
B. Effectiveness of forced draft cooling tower is reduced by the recirculation of the humid and
hot discharged air
C. A natural draft cooling tower is recommended to be used, when the air humidity is low and air
temperature is also low
D. Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb
temperature - Use of packed towers for distillation is generally limited to the____________________?
A. Small sizes
B. Multi-component distillation
C. High pressure operation
D. Vacuum distillation