A. Increase
B. Decrease
C. Not affect
D. Increase the condensing film co-efficient as well as
Related Mcqs:
- Presence of a non-condensing gas in a condensing vapour___________________?
A. Increases the rate of condensation
B. Decreases thermal resistance
C. Is desirable to increase the film co-efficient
D. None of these - The film co-efficient is decreased due to the presence of non-condensing gases in the vapors. The film co-efficient of superheated vapor as compared to that of saturated vapor is___________________?
A. More
B. Less
C. Some
D. Either more or less; depends on the nature of vapor - Condensing film co-efficient for steam on horizontal tubes ranges from 5000 to 15000 Kcal/hr.m2.°C. Condensation of vapor is carried out inside the tube in a shell and tube heat exchanger, when the_________________?
A. Higher condensing film co-efficient is desired
B. Condensate is corrosive in nature
C. Lower pressure drop through the exchanger is desired
D. Temperature of the incoming vapor is very high - In a co-current double pipe heat exchanger used for condensing saturated steam over the inner tube, if the entrance and exit conditions of the coolant are interchanged, then the rate of condensation will___________________?
A. Increase
B. Decrease
C. Remain unchanged
D. Either increase or decrease; depends on the coolant flow rate - Removal of ______________ heat is involved in the condensation of a vapor under saturated conditions?
A. Super
B. Sensible
C. Latent
D. Both B. & C. - The heat transfer co-efficient in film type condensation is _______________ that for dropwise condensation?
A. Greater than
B. Lower than
C. Is same as
D. Half - For condensation of pure vapors, if the heat transfer co-efficients in filmwise and drop-wise condensation are respectively hf and hd, then__________________?
A. hf = hd
B. hf > hd
C. hf < hd
D. hf could be greater or smaller than hd - Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both the cases. The recommended arrangement is________________?
A. Finned tube heat exchanger with air inside and steam outside
B. Finned tube heat exchanger with air outside and steam inside
C. Shell and tube heat exchanger with air inside tubes and steam on shell side
D. Shell and tube heat exchanger with air on shell side and steam inside tubes - LMTD for evaporators & condensers for a given terminal parameters & set of conditions for counter-flow is equal to that for parallel flow. In such heat exchangers, with one of the fluids condensing or evaporating, the surface area required is the least in the ______________ flow?
A. Parallel
B. Mixed
C. Counter flow
D. Same in either A , B. or C. - A single pass air heater is connected to a two pass unit. For the air flow rate and other conditions remaining the same, the film heat transfer co-efficient for air will vary in the ratio of__________________?
A. 2
B. 20.8
C. 20.2
D. 20.5