A. Resistances in parallel
B. Capacitors in series
C. Resistances in series
D. None of these
Related Mcqs:
- Heat flux increases with temperature drop beyond the Leiden frost point in the plot of heat flux vs. temperature drop for a boiling liquid, because___________________?
A. Convection becomes important
B. Conduction becomes important
C. Radiation becomes important
D. Sub-cooled boiling occurs - The overall resistance for heat transfer through a series of flat resistance, is the _____________ of the resistances?
A. Average
B. Geometric mean
C. Product
D. Sum - Overall thermal resistance for conductive heat transfer through a series of flat resistances is equal to the____________________?
A. Maximum resistance in the series
B. Sum of all resistances
C. Average of all resistances
D. Minimum resistance presents in the series - The radiation heat flux from a heating element at a temperature of 800°C, in a furnace maintained at 300°C is 8 kW/m2. The flux, when the element temperature is increased to 1000°C for the same furnace temperature is_____________________?
A. 11.2 kW/m2
B. 12.0 kW/m2
C. 14.6 kW/m2
D. 16.5 kW/m2 - Heat flux, as defined in heat flow is analogous to _______________ in electricity flow?
A. Current
B. Voltage
C. Resistance
D. None of these - Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both the cases. The recommended arrangement is________________?
A. Finned tube heat exchanger with air inside and steam outside
B. Finned tube heat exchanger with air outside and steam inside
C. Shell and tube heat exchanger with air inside tubes and steam on shell side
D. Shell and tube heat exchanger with air on shell side and steam inside tubes - A 10 cm dia steam pipe, carrying steam at 180°C, is covered with an insulation (conductivity = 0.6 W/m.°C). It losses heat to the surroundings at 30°C. Assume a heat transfer co-efficient of 0.8 W/m2.°C for heat transfer from surface to the surroundings. Neglect wall resistance of the pipe and film resistance of steam. If the insulation thickness is 2 cms, the rate of heat loss from this insulated pipe will be__________________?
A. Greater than that for un-insulated steam pipe
B. Less than that of the un-insulated steam pipe
C. Equal to that of the un-insulated steam pipe
D. Less than the steam pipe with 5 cms insulation - Extended heat transfer surface like fins are used to increase the heat transfer rate. Fin efficiency is defined as the ratio of heat transferred across the fin surface to the theoretical heat transfer across an equal area held at the________________?
A. Surrounding temperature
B. Average temperature of the fin
C. Temperature of the fin end
D. Constant temperature equal to that of the base - If average heat transfer co-efficient is ha and the local coefficient at the end of the plate is hl then in case of heat transfer to a fluid flowing over a flat plate, heated over its entire length________________?
A. ha = hl
B. ha = 2hl
C. ha = 0.5 hl
D. ha = 0.75 hl - A fluid is flowing inside the inner tube of a double pipe heat exchanger with diameter ‘d’. For a fixed mass flow rate, the tube side heat transfer co-efficient for turbulent flow conditions is proportional to_____________________?
A. d0.8
B. d-0.2
C. d-1
D. d-1.8