A. < 1
B. > 1
C. 1
D. ∞
Related Mcqs:
- LMTD for counter-flow and parallel flow heat exchanger will be the same, when the_________________?
A. Cold fluid is heated to a certain temperature by condensing steam (isothermal fluid)
B. Outlet temperature of both the hot and cold fluid are same
C. Outlet temperature of hot fluid is less than the outlet temperature of the cold fluid
D. None of these - LMTD correction factor which is to be applied for a cross-flow heat exchanger increases with increase in the number of shell passes. Its value for a single pass cross flow heat exchanger is __________________?
A. 0
B. 1
C. > 1
D. < 1 - LMTD for evaporators & condensers for a given terminal parameters & set of conditions for counter-flow is equal to that for parallel flow. In such heat exchangers, with one of the fluids condensing or evaporating, the surface area required is the least in the ______________ flow?
A. Parallel
B. Mixed
C. Counter flow
D. Same in either A , B. or C. - In a parallel flow heat exchanger, if the outlet temperature of hot and cold fluids are the same, then the log mean temperature difference (LMTD) is_________________?
A. Minimum
B. Maximum
C. Zero
D. Infinity - 1000 Kg of liquid at 30°C in a well stirred vessel has to be heated to 120°C, using immersed coils carrying condensing steam at 150°C. The area of the steam coils is 1.2 m2 and the overall heat transfer co-efficient to the liquid is 1500 W/m2.°C. Assuming negligible heat loss to the surrounding and specific heat capacity of the liquid to be 4 kJ/kg.°C, the time taken for the liquid to reach desired temperature will be__________________?
A. 15 min
B. 22 min
C. 44 min
D. 51 min - Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both the cases. The recommended arrangement is________________?
A. Finned tube heat exchanger with air inside and steam outside
B. Finned tube heat exchanger with air outside and steam inside
C. Shell and tube heat exchanger with air inside tubes and steam on shell side
D. Shell and tube heat exchanger with air on shell side and steam inside tubes - For a counter current heat exchanger with Ti h = 80°C, T°c = 60°C, T°h = 50°C and Ti c = 30°C, and the temperature difference between the two streams being the same everywhere along Z, the direction of flow of hot fluid. The temperature profile should satisfy___________________?
A. d2T/dZ2 > 0
B. d2T/dZ2 = 0
C. d2T/dZ2 < 0
D. dT/dZ = 0 - In a 1-1 concurrent heat exchanger, if the tube side fluid outlet temperature is equal to the shell side fluid outlet temperature, then the LMTD is_________________?
A. ∞
B. 0
C. Equal to the difference between hot and cold fluids inlet temperature
D. Equal to the difference between hot fluid inlet temperature and cold fluid outlet temperature - In case of parallel flow heat exchanger, the lowest temperature theoretically attainable by the hot fluid is _____________ the outlet temperature of the cold fluid?
A. Equal to
B. More than
C. Less than
D. Either more or less than (depending upon the fluid) - It is not recommended to use a 1-2 shell and tube heat exchanger for a particular heat duty, whenever the LMTD correction factor is___________________?
A. > 0.75
B. < 0.75
C. < 0.50
D. < 0.25