A. Economiser
B. Regenerator
C. Ceramic recuperator
D. None of these
Related Mcqs:
- An equipment which converts the latent or sensible heat of one fluid into the latent heat of vaporisation of another, is called a_________________?
A. Boiler
B. Heat exchanger
C. Recuperator
D. Regenerator - Sensible heat absorbed by 1 lb of water when it is heated from 32 to 212°F may be around ______________ BTU?
A. 180
B. 970
C. 3.97
D. Data insufficient, can’t be predicted - Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both the cases. The recommended arrangement is________________?
A. Finned tube heat exchanger with air inside and steam outside
B. Finned tube heat exchanger with air outside and steam inside
C. Shell and tube heat exchanger with air inside tubes and steam on shell side
D. Shell and tube heat exchanger with air on shell side and steam inside tubes - A 10 cm dia steam pipe, carrying steam at 180°C, is covered with an insulation (conductivity = 0.6 W/m.°C). It losses heat to the surroundings at 30°C. Assume a heat transfer co-efficient of 0.8 W/m2.°C for heat transfer from surface to the surroundings. Neglect wall resistance of the pipe and film resistance of steam. If the insulation thickness is 2 cms, the rate of heat loss from this insulated pipe will be__________________?
A. Greater than that for un-insulated steam pipe
B. Less than that of the un-insulated steam pipe
C. Equal to that of the un-insulated steam pipe
D. Less than the steam pipe with 5 cms insulation - Extended heat transfer surface like fins are used to increase the heat transfer rate. Fin efficiency is defined as the ratio of heat transferred across the fin surface to the theoretical heat transfer across an equal area held at the________________?
A. Surrounding temperature
B. Average temperature of the fin
C. Temperature of the fin end
D. Constant temperature equal to that of the base - In a heat exchanger, the rate of heat transfer from the hot fluid to the cold fluid___________________?
A. Varies directly as the area and the LMTD
B. Directly proportional to LMTD and inversely proportional to the area
C. Varies as square of the area
D. None of these - Hot water (0.01 m3 /min) enters the tube side of a counter current shell and tube heat exchanger at 80°C and leaves at 50°C. Cold oil (0.05 m3/min) of density 800 kg/m3 and specific heat of 2 kJ/kg.K enters at 20°C. The log mean temperature difference in °C is approximately ?
A. 32
B. 37
C. 45
D. 50 - Heat transfer by conduction results due to the transfer of free electrons, kinetic energy & vibrational energy from one molecule to another. Conduction heat transfer cannot take place____________________?
A. Between two bodies in physical contact with each other
B. Between two bodies not in physical contact with each other
C. From one part of a body to the another part of the same body
D. Both B & C - Fouling factor for a heat exchanger is given by (where, U1 = heat transfer co-efficient of dirty surface U2 = heat transfer co-efficient of clean surface) ?
A. U1 – U2
B. 1/U1 – 1/U2
C. 1/U2 – 1/U1
D. U2 – U1 - The overall heat transfer co-efficient for a shell and tube heat exchanger for clean surfaces is U0 = 400 W/m2.K. The fouling factor after one year of operation is found to be hd0 = 2000 W/m2.K. The overall heat transfer co-efficient at this time is _____________________?
A. 1200 W/m2.K
B. 894 W/m2.K
C. 333 W/m2.K
D. 287 W/m2.K