A. Cold fluid is heated to a certain temperature by condensing steam (isothermal fluid)
B. Outlet temperature of both the hot and cold fluid are same
C. Outlet temperature of hot fluid is less than the outlet temperature of the cold fluid
D. None of these
Related Mcqs:
- In a liquid-liquid heat exchanger, for the same process temperature, the ratio of the LMTD in parallel flow to the LMTD in counter flow is always__________________?
A. < 1
B. > 1
C. 1
D. ∞ - LMTD correction factor which is to be applied for a cross-flow heat exchanger increases with increase in the number of shell passes. Its value for a single pass cross flow heat exchanger is __________________?
A. 0
B. 1
C. > 1
D. < 1 - LMTD for evaporators & condensers for a given terminal parameters & set of conditions for counter-flow is equal to that for parallel flow. In such heat exchangers, with one of the fluids condensing or evaporating, the surface area required is the least in the ______________ flow?
A. Parallel
B. Mixed
C. Counter flow
D. Same in either A , B. or C. - In a parallel flow heat exchanger, if the outlet temperature of hot and cold fluids are the same, then the log mean temperature difference (LMTD) is_________________?
A. Minimum
B. Maximum
C. Zero
D. Infinity - Air is to be heated by condensing steam. Two heat exchangers are available (i) a shell and tube heat exchanger and (ii) a finned tube heat exchanger. Tube side heat transfer area are equal in both the cases. The recommended arrangement is________________?
A. Finned tube heat exchanger with air inside and steam outside
B. Finned tube heat exchanger with air outside and steam inside
C. Shell and tube heat exchanger with air inside tubes and steam on shell side
D. Shell and tube heat exchanger with air on shell side and steam inside tubes - It is not recommended to use a 1-2 shell and tube heat exchanger for a particular heat duty, whenever the LMTD correction factor is___________________?
A. > 0.75
B. < 0.75
C. < 0.50
D. < 0.25 - Out of the following four assumptions used in the derivation of the equation for LMTD [LMTD = (Δt1 – Δt2)/ln(Δt1/Δt2)], which one is subject to the largest deviation in practice ?
A. Constant overall heat transfer co-efficient.
B. Constant rate of fluid flow
C. Constant specific heat
D. No partial phase change in the system - Hot water (0.01 m3 /min) enters the tube side of a counter current shell and tube heat exchanger at 80°C and leaves at 50°C. Cold oil (0.05 m3/min) of density 800 kg/m3 and specific heat of 2 kJ/kg.K enters at 20°C. The log mean temperature difference in °C is approximately ?
A. 32
B. 37
C. 45
D. 50 - For a counter current heat exchanger with Ti h = 80°C, T°c = 60°C, T°h = 50°C and Ti c = 30°C, and the temperature difference between the two streams being the same everywhere along Z, the direction of flow of hot fluid. The temperature profile should satisfy___________________?
A. d2T/dZ2 > 0
B. d2T/dZ2 = 0
C. d2T/dZ2 < 0
D. dT/dZ = 0 - For a multipass shell and tube heat exchanger, the LMTD correction factor is always________________?
A. 1
B. > 1
C. < 1
D. Between 1 & 2