A. Series generator
B. Shunt generator
C. Compound generator
D. None of the above
Related Mcqs:
- Following D.C. generator will be in a position to build up without any residual magnetism in the poles______________?
A. series generator
B. shunt generator
C. compound generator
D. self-excited generator - Two generators are running in parallel. One of the generators may run as motor for which of the following reasons ?
A. The direction of that generator is reversed
B. The speed of that generator is increased
C. The field of that generator is weakened
D. That generator takes large share of loads - Two generators A and B have 6-poles each. Generator A has wave wound armature while generator B has lap wound armature. The ratio of the induced e.m.f. is generator A and B will be_______________?
A. 2 : 3
B. 3 : 1
C. 3 : 2
D. 1 : 3 - If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be____________?
A. zero
B. small
C. the same as rated voltage
D. high - Which of the following statement about D.C. generators is false ?
A. Compensating winding in a D.C. machine helps in commutation
B. In a D. C. generator interpoles winding is connected in series with the armature winding
C. Back pitch and front pitch are both odd and approximately equal to the pole pitch
D. Equilizing bus bars are used with parallel running of D.C. shunt gen¬erators - Which of the following generators will be preferred if they are required to be run in parallel?
A. Shunt generators
B. Series generators
C. Compound generators
D. None of the above - For a D.C. generator when the number of poles and the number of armature conductors is fixed, then which winding will give the higher e.m.f___________ ?
A. Lap winding
B. Wave winding
C. Either of A. and B. above
D. Depends on other features of design - In D.C. generators the polarity of the interpoles_____________?
A. is the same as that of the main pole ahead
B. is the same as that of the immediately preceding pole
C. is opposite to that of the main pole ahead
D. is neutral as these poles do not play part in generating e.m.f. - Two D.C. shunt generators, each with armature resistance of 0.02 ohm and field resistance of 50 ohm run in parallel and supply a total current of 1000 amperes to the load circuit. If their e.m.fs. are 270 V and 265 V, their bus bar voltage will be_____________________?
A. 270 V
B. 267.5 V
C. 265 V
D. 257.4 V - The essential condition for parallel operation of two D.C. generators is that they have ________________?
A. same kW rating
B. the same operation r.p.m.
C. the same drooping voltage characteristics
D. same percentage regulation