A. Decreases
B. Increases
C. Remain unaffected
D. May increase or decrease depending upon whether the fluid is Newtonian or non-Newtonian
Related Mcqs:
- For turbulent flow (NRe > 2100) of low viscosity fluid (μ > 20cp) in steel pipes, the optimum inside pipe diameter is given by(where, Q = fluid flow rate, ft3/sec, ρ = fluid density, lb/ft3 μ = fluid viscosity, centipoise Di = optimum inside pipe diameter, inches) ?
A. Di, opt = 3.9 Q0.45 ρ0.13
B. Di, opt = 3.9 Q0.45. μ0.95
C. Di, opt = 4.7 Q0.36. μ3.2ρ0.13
D. Di, opt = 3 Q0.36. μ0.88 - For laminar flow (NRe < 2100) in steel pipe, the optimum inside pipe diameter is given by____________________?
A. Di, opt = 3 Q0.36 ρ0.18
B. Di, opt = 3.9 Q0.45 ρ0.23
C. Di, opt = 7.6 Q0.36 ρ0.9
D. Di, opt = 3 Q0.36 ρ1.86 μ0.08 - In a shell and tube heat exchanger for a given heat transfer surface area, smaller diameter tubes are favoured as compared to larger diameter ones; because the smaller diameter tubes ______________?
A. Are easier to clean
B. Are less prone to fouling
C. Can be fitted into a smaller shell diameter hence the cost of the heat exchanger would be less
D. None of these - The equivalent diameter for fluid flow through a channel of constant non-circular cross section of area ‘A’ is given by (where, P = perimeter of the channel in contact with the fluid) ?
A. 4 A/P
B. A/P
C. 4 P/A
D. √A - For pipe flows, head is proportional to ______________ at constant capacity (where D = pipe diameter) ?
A. 1/D
B. 1/D2
C. 1/D5
D. D2 - Optimum economic pipe diameter for fluid flow is determined by the____________________?
A. Viscosity of the fluid
B. Density of the fluid
C. Total cost considerations (pumping cost plus fixed cost of the pipe)
D. None of these - Multiple blade paddle agitator is used for mixing high viscosity liquids/paste in which the paddle diameter is commonly 0.8 times the tank diameter. However, the width of the blade is in the range of ______________ times the paddle diameter?
A. 0.1 to 0.25
B. 0.3 to 0.5
C. 0.5 to 0.6
D. 0.65 to 0.80 - For annular flow of a fluid, the ratio of the equivalent diameter for pressure drop calculation to the equivalent diameter for heat transfer calculation is_________________?
A. d1/(d1 + d2)
B. d2/(d1 + d2)
C. (d1 + d2)/d1
D. (d1 + d2)/d2 - In a shell and tube heat exchanger having square pitch, the shell side equivalent diameter is given by (where, P = pitch, d = outside diameter of the tube) ?
A. 4(P2 – πd2/4)/πd
B. (P2 – rd2/4)/rd
C. 4P2/πd
D. πd/4P2 - For given number of passes, pitch & tube diameter, the maximum number of tubes that can be accommodated in a shell of tripled inside diameter will be ____________ times?
A. About 9
B. Considerably more than 9
C. Considerably less than 9
D. About 3